PEC017
5/3/2018
Page
61
of
105
N081
Page
Min
Default
Max
Units
PTO Mode Maximum Engine Speed
Rate of Change
50
75
200
RPM/SEC
* To Enable,
Enable PTO Mode Engine Ramp Rate Limiter (N109)
must be ON
N086
Page
Min
Default
Max
Units
Maximum Engine Speed using
Switch Inputs
N106
2000
2000
RPM
* Must be greater than or equal to
PTO Mode Minimum Engine Speed (N106)
*
For Remote applications, shoul
d be set to Customer’s requested Maximum
Engine Speed
N106
Page
Min
Default
Max
Units
PTO Mode Minimum Engine Speed
N052
650
2000
RPM
* Must be greater than or equal to
Engine Idle Speed (N052)
* May not be greater than 800 RPM if
Require Parking Brake for PTO Mode
(N079)
Neutral Required for PTO Mode (N089)
are disabled
* May not be greater than 950 RPM if
Require Parking Brake for PTO Mode
(N079)
Neutral Required for PTO Mode (N089)
are disabled, and
is enabled.
N109
Page
Min
Default
Max
Units
Enable PTO Mode Engine Ramp
Rate Limiter
OFF (0)
OFF (0)
ON (1)
ON/OFF
In-Cab Control Configuration, Limits, and Set Points
N082
Page
Min
Default
Max
Units
Engine Speed Decrease w/
Res/Decel (In-Cab)
10
50
1000
RPM
N083
Page
Min
Default
Max
Units
Engine Speed Increase w/ Set/Accel
(In-Cab)
10
50
1000
RPM
N084
Page
Min
Default
Max
Units
Engine Speed Ramp-down
w/Res/Decel (In-Cab)
10
250
1000
RPM/SEC
Содержание MX Series
Страница 1: ...PEC017 5 3 2018 Programming Guide EPA 2017 ...
Страница 9: ...PEC017 5 3 2018 Page 9 of 105 Graph 4 2 MX 13 Power and Torque Curves for Multi Torque Ratings ...
Страница 11: ...PEC017 5 3 2018 Page 11 of 105 Graph 4 4 MX 11 Power and Torque Curves for Multi Torque Ratings ...
Страница 43: ...PEC017 5 3 2018 Page 43 of 105 Graph 11 2 MX 11 Engine Brake Performance Curves ...