PEC017
5/3/2018
Page
95
of
105
N102
Page
Min
Default
Max
Units
Signal Source for Remote Main
Switch
0
0
1
N/A
* 0 = Hardwired 12V
1 = CAN Signal
N103
Page
Min
Default
Max
Units
Engine Speed Increase w/ Set/Accel
10
250
1000
RPM/SEC
N104
Page
Min
Default
Max
Units
Engine Speed Decrease w/
Res/Decel
10
250
1000
RPM/SEC
N105
Page
Min
Default
Max
Units
Engine Speed Ramp-down w/
Res/Decel
10
100
1900
RPM
N106
Page
Min
Default
Max
Units
PTO Mode Minimum Engine Speed
N052
650
2000
RPM
* Must be greater than or equal to
Engine Idle Speed (N052)
* May not be greater than 800 RPM if
Require Parking Brake for PTO Mode
(N079)
Neutral Required for PTO Mode (N089)
are disabled
* May not be greater than 950 RPM if
Require Parking Brake for PTO Mode
(N079)
Neutral Required for PTO Mode (N089)
are disabled, and
is enabled.
N107
Page
Min
Default
Max
Units
Engine Speed Ramp-Up w/
Set/Accel
10
100
1900
RPM
N109
Page
Min
Default
Max
Units
Enable PTO Mode Engine Ramp
Rate Limiter
OFF (0)
OFF (0)
ON (1)
ON/OFF
Содержание MX Series
Страница 1: ...PEC017 5 3 2018 Programming Guide EPA 2017 ...
Страница 9: ...PEC017 5 3 2018 Page 9 of 105 Graph 4 2 MX 13 Power and Torque Curves for Multi Torque Ratings ...
Страница 11: ...PEC017 5 3 2018 Page 11 of 105 Graph 4 4 MX 11 Power and Torque Curves for Multi Torque Ratings ...
Страница 43: ...PEC017 5 3 2018 Page 43 of 105 Graph 11 2 MX 11 Engine Brake Performance Curves ...