46
multipath software so that your operating system can
identify alternate paths to the same logical drive.
RAID
configuration
Remote replication functionality is not supported
using this configuration. For remote replication
setup, please refer to “
High Availability IP SAN
(Remote Replication Enabled)
or “
High Availability
IP SAN with Port Trunk (Remote Replication
Enabled)
”.
4 logical drives (each has 4 member drives; for better
performance, you can include drives from the expansion
enclosure)
LD0 mapped to CH0 AID and CH0 BID; LD assigned to
controller A
LD1 mapped to CH1 AID and CH1 BID; LD assigned to
controller A
LD2 mapped to CH2 AID and CH2 BID; LD assigned to
controller B
LD3 mapped to CH3 AID and CH3 BID; LD assigned to
controller B
*
LD assignment
NOTE
In the event of Single-Controller failure, a logical drive is accessed through the host
IDs managed by the alternate controller. Host IDs and port IPs do not fail-over to
the surviving controller. Therefore, the MPIO multipath driver is necessary for path
redundancy and controller failover.