Picture 1. Front of the device.

Basic operation of the device is done by setting desired temperature with boiler

thermostat knob, other functions are realized according to parameters programmed in

service mode. While changing boiler temperature settings with the knob, the change is

displayed on the display for a few seconds (for example

[C 55]

) and this value means

the temperature, which the controller will be trying to achieve. You can check this

value by pressing OK button.

If heating installation is equipped with indoor temperature sensor, room thermostat

knob can be used to set desired room temperature. Change of this value is indicated

on the display for a few seconds in the display eg.:

[ 20°]

.

After pressing START button, the fan starts to work and the control process begins.

STOP button stops the fan, for example allowing to add fuel to the boiler.

If the controller isn't in service mode, the display shows water temperature of the boiler

and the last sign on the display defines mode, which controller currently is in:

for example:

[50º-]

– STOP mode

[50ºC]

– WORK mode

[50ºc]

– keeping fire in WORK mode

4. Setting up the parameters - service mode.

Holding OK button for more than 3 seconds causes change to service mode, where

you can view and change programmed parameters. Service mode is indicated by

flashing of the room thermostat indicator. You can look through parameters with + and

- buttons. After choosing desired parameter, you can switch to change mode of the

parameter by pressing OK button - this mode is indicated by value of the parameter

flashing. Change of the parameter is possible by pressing - or + buttons. You can

confirm new settings by OK button and after that there is possible to choose another

parameter (with +,- buttons). If you want to quit service mode , choose [End ] option

with + and - buttons and press OK; or wait 1 minute. The device will exit service mode

and will start to indicate boiler temperature.

Содержание RK-2001E2-D

Страница 1: ...OPERATION MANUAL SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER RK 2001E2 D Version 9A15...

Страница 2: ......

Страница 3: ...placed in measurement hole in the boiler Picture 2 shows diagram of electrical connection of the device WARNING Before plugging the device to the power source check if it is proprerly grounded and if...

Страница 4: ...ler If the controller isn t in service mode the display shows water temperature of the boiler and the last sign on the display defines mode which controller currently is in for example 50 STOP mode 50...

Страница 5: ...olling emergency cooling system 4 output controlling extra devices turning on during work of blow in fan 0 4 1 0 Prod Return to factory defaults outP Central heating pump testing outP out1 out Fan out...

Страница 6: ...in the boiler which causes start of the circulating pump Circulating pump works independently from the control process and is launched additionally in case of boiler overheat Circulating pump launch...

Страница 7: ...o previous mode by pressing STOP button No fuel testing time during fuel firing is finished after the set temperature is achieved No fuel testing time during work mode Fb30 in WORK mode if temperature...

Страница 8: ...set by the producer by choosing Prod option in service mode and pressing OK button After activating this function the device sets each parameter showed in the table to default 4 9 Exiting service mode...

Страница 9: ...d if boiler overheats E 3 error means fault and overheating at the same time Appearing of E 1 error on the display without ability to cancel it by pressing STOP button in spite of temperature below 90...

Страница 10: ...10 Picture 2 RK 2001E2 connection scheme Picture 3 UM 1 module connection scheme...

Страница 11: ...2 The work mode and pause time of CH pump L 65 Minimum boiler temperature H 85 Maximum boiler temperature h 2 Boiler temperature hysteresis A 99 Boiler overheating temperature Fd60 Fuel shortage testi...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ......

Страница 16: ...Producer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Отзывы: