15
MAN 9058634 EN V1
P. Lindberg A/S
Sdr. Ringvej 1
www.p-lindberg.dk
Tel.: +45 70 21 26 26
DK-6600 Vejen
e-mail: [email protected]
Spark plug:
Clean and adjust after every 600 operating hours or as required:
-
Remove the top shield.
-
Remove the fan.
-
Remove the ignition lead from the spark plug.
-
Remove the spark plug from the burner head.
-
Clean and adjust the electrodes (3.5 mm).
-
Replace the spark plug on the burner head.
-
Replace the lead on the spark plug.
-
Replace the fan and the top shield.
Photo cell:
Clean the photo cell once a year or as required:
-
Remove the top shield.
-
Remove the fan.
-
Remove the photo cell from the holder.
-
Clean the photo cell with a cotton bud.
If the photo cell needs to be replaced:
-
Remove the side panel by the switch.
-
Remove the wires from the circuit board
and remove the photo cell.
-
Insert the new photo cell and attach the
wires to the circuit board.
-
Replace the fan and the top shield.
Spark plug lead
Gap
Burner head
Spark plug
Photo cell lead
Circuit board
3VE49A Only