WARNING:
Risk of burns, fire or explosion
•
NEVER use fuels such as petrol, benzene, thinner or other oil compositions in this
indirect air heater (RISK OF FIRE OR EXPLOSION).
•
NEVER use the indirect air heater in places where flammable vapours may be present.
•
Never fill with fuel while the indirect air heater is operating or still hot. The indirect air
heater gets extremely hot when operating.
•
Keep flammable materials away from the indirect air heater.
WARNING:
Do not remove the plug before the indirect air heater has cooled down.
•
NEVER remove the plug before the indirect air heater has cooled down. Wait at least
three minutes before removing the plug to prevent damage to the equipment.
•
Minimum distances:
Exhaust: 250 cm
Sides, top and intake: 125 cm
•
Never block the intake or exhaust.
•
NEVER use pipes, either on the front or rear of the indirect air heater.
•
NEVER move the indirect air heater while it is still hot.
•
NEVER transport the indirect air heater with fuel in the tank.
•
ALWAYS position the indirect air heater on a flat and stable surface.
•
ALWAYS keep children and animals at a safe distance.
•
ALWAYS use diesel oil to fuel the indirect air heater.
•
Fuel containers must always be stored in accordance with local regulations at least 8
metres away from the indirect air heater and other ignition sources.
WARNING:
Risk of electric shock.
•
ALWAYS ensure that the power supply (voltage and frequency) matches the
specifications of the indirect air heater. Use only 3-pin plugs and extension cables with
an earth connection.
•
ALWAYS position the indirect air heater so it is protected from direct water spray, rain,
dripping water and wind.
•
ALWAYS unplug the indirect air heater when it is not in use.