9
Follow these steps to clean the device:
a.
Pull the power plug of the device and open the silver cover at the front to clean out the
Plasma discharge electrode.
b.
Underneath there is the plasma discharge electrode. The plasma plate does not necessarily
need to be demounted for cleaning. Check the electrode during cleaning on potential cracks
or fractures.
c. Begin cleaning the electrode with a damp cloth. If you use a dry cloth for cleaning, make sure it is
without any fluffs, since they might lead to damages on the electrode. Be careful not to damage
the electrode during cleaning.
d. Make sure the electrode is absolutely dry before operating again.
If you the electrode is much heavier polluted you might have to demount the electrode:
a. Loosen the electrode from its attachment, since they are only clipped in.
b. After demounting the plate it can be cleaned carefully under clear water with a mild soap
solution (e.g. dishwashing detergent).
c. The device can be remounted after it has fully dried.
12 Bug fixing
Bug
Potential cause
Device produces less / no ozone
If the air fan is functioning and there was still no discharge it might
be due to polluted electrodes. Clean those according to the
instructions.
Device does not start
Check power (230V / 50 Hz). Check power plug on any damages.
Change the fuse, if necessary (2A
– flink)
13 Optional Equipment / Replacements
-
Plasma electrode
-
High voltage transformer
-
Remote control