EN
9
5.
Use the timer setting button (3) to set the desired period of operation as follows:
Press the button for approx. two seconds, thus setting a 15-minute period of operation. Each time
you press the button again, you double the operating time up to eight hours. Available periods are:
15 minutes, 30 minutes, one hour, two hours, four hours and eight hours. The remaining time period
is shown on the timer display (2). Simply push the timer setting button again to change the period of
operation while the device is operating.
6.
The device will begin to emit ozone at the back of the machine (9). LEAVE THE ROOM
IMMEDIATELY!
7.
Once the set period of operation is over, the device will stop. Wait for one more hour before
entering the room. Ozone is very unstable. It remains in the air for about 30 minutes, after
which it becomes oxygen again if nothing remains for it to oxidize. Therefore, 30 minutes
after the treatment has stopped, ozone concentration starts to fall significantly. It reaches a
safe level in roughly one hour.
ATTENTION! These are estimated time periods, based on previous experience. They depend on a
number of variables (temperature, humidity etc.). A safe level can be precisely determined with a
special gauge prepared specifically for this purpose. If you do not have this instrument, please wait
more than one hour, if possible, before entering the room.
8.
Air the treated room thoroughly.
9.
If the process needs to be repeated continuously, wait at least 30 minutes after turning the
device off. Although the device can operate for eight hours non-stop, it is not recommended
that it be used for over four hours since it may shorten the lifespan of the ceramic tiles that
produce the ozone in the machine.
WARNING! In case of a breakdown or malfunction, cut the power supply
immediately by turning off the machine with the on/off switch (4) and
pulling the power cable out of the outlet. In the event that ozone production
has already started, leave the room immediately after turning off the
power. Turn to the manufacturer or seller of the device. The ozone
generator has no parts that may be repaired at home, so please do not do
any repair work on your own.
3
MAINTENANCE
3.1
GENERAL INFORMATION
This chapter contains information on maintenance that the user can also perform. Generators require
very little maintenance work if the basic requirements for safe operation are met and the user follows
the instructions in the operating manual. Still, certain elements must be regularly inspected.
Содержание PRO 30000 TS