The battery (6) has been shipped in a low charge condition, and require charging prior
to use. 

Plug the charger adaptor (9) into a mains power outlet.

The green light on the adaptor (9) will illuminate
showing that power is being supplied to the 
adaptor (9). 

With the battery (6) sitting flat on a bench/table, align
the “+” and “-“ symbols on both the battery (6) and
charger connector (10), slide the charger connector (10)
into the recess of the battery (6) terminals ensuring a
firm connection (Fig. 1).

The charger connecter (10) only fits one way. If the charger connector (10) will not
fit it means it is  upside down.

When the battery (6) and charger adaptor (9) is properly connected, the light on the
charger adaptor (9) will illuminate red signifying that the battery (6) is on charge.

When fully charged, the light on the charger adaptor (9) will illuminate green. 

A battery (6) takes 2 hours to charge. Charging starts automatically. Remove the
battery (6) from the charging connector (10) after no more than 5 hours charging.

Initial charge

The battery (6) will not reach its full charge the first time it is charged. The red light
will remain illuminated until the charger adaptor (9) is disconnected from the
power source. 

Allow several charging cycles of charging and then discharging (through use of the
tool) for the battery (6) to reach its maximum charge. 

Caution: 

Remove the charger adaptor (9) from the mains power outlet when charger is

not in use. 

Note:

If the light on the charger adaptor (9) fails to come on:

- Check the charging adaptor (9) is securely plugged into the mains power outlet 

and switched on. 

- Check the charging connector (10) is securely connected into the socket of the 

battery (6).  

Subsequent charges 

After normal usage, approximately 2 hours of charging time is required to fully
recharge the battery (6). 

If the battery (6) is completely discharged, 5 hours or longer of charging time will
be required to fully recharge it. 

CHARGING YOUR LITHIUM ION BATTERY

Fig. 1

 

 

 

 

 

 

 

 

 

 

 

 

Содержание LBL-018

Страница 1: ......

Страница 2: ...vel of this machine can exceed 85db A Operators are recommended to use hearing protection devices 1 Air output 2 Blower tube 3 Blower tube release button 4 On off switch 5 Operation handle with soft g...

Страница 3: ...Y AND CHARGER SAFETY WARNINGS ADDITIONAL SAFETY RULES FOR BLOWER CHARGING YOUR LITHIUM ION BATTERY INSTALLING OR REMOVING THE BATTERY OPERATION MAINTENANCE SPARE PARTS DESCRIPTION OF SYMBOLS PACK CONT...

Страница 4: ...ly It is not built for continuous daily use in a trade or professional capacity ELECTRICAL SAFETY THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR YOUR BATTERY CHARGER Before using...

Страница 5: ...power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving part...

Страница 6: ...ing any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of chi...

Страница 7: ...blow been dropped or otherwise damaged in any way Have it checked by an electrician or power tool repairer Do not disassemble charger Take it to an electrician or power tool repairer when service or r...

Страница 8: ...to another Do not operate the tool near children or pets Maintain a safe distance of at least 5m from other people when using the tool Never direct the blower direction nozzle towards bystanders or pe...

Страница 9: ...ge Charging starts automatically Remove the battery 6 from the charging connector 10 after no more than 5 hours charging Initial charge The battery 6 will not reach its full charge the first time it i...

Страница 10: ...the blower Do not continue to press the on off switch 4 after an automatic shut off as it will damage the battery The battery must be re charged before further use Note if battery is flat and display...

Страница 11: ...lease button 7 and pull the battery 6 away from the blower See Fig 3 Getting the best performance from the battery The length of service from each charging cycle will depend on the type of work undert...

Страница 12: ...me warm to touch This is normal and doesn t indicate a problem Note Keep the vents of the air intake port 8 free from leaves and debris DO NOT BLOCK AIR INTAKE PORT 8 Blocking the air intake port 8 du...

Страница 13: ...uires cleaning do not use solvents but a moist soft cloth only Note Ozito Industries will not be responsible for any damage or injuries caused by repair of the tool by an unauthorised person or by mis...

Страница 14: ...ery Do not put in the rubbish Isolation transformer Polarity Do not incinerate Do not get battery wet Thermal cut out protection at 130 C Transformer Energy Rating MEPS Double insulated min Revolution...

Страница 15: ...u Power tools that are no longer usable should not be disposed of with household waste but in an environmentally friendly way Please recycle where facilities exist Check with your local council author...

Страница 16: ...s will result in the warranty being void If the tool has been operated on a supply voltage other than that specified on the unit If the tool shows signs of damage or defects caused by or resulting fro...

Отзывы: