background image

DESCRIPTION OF SYMBOLS

CARING FOR THE ENVIRONMENT

Power tools that are no longer usable should not be disposed of 

with household waste but in an environmentally friendly way. Please 

recycle where facilities exist. Check with your local council authority 

for recycling advice.

Recycling packaging reduces the need for landfill and raw materials. 

Reuse of recycled material decreases pollution in the environment. 

Please recycle packaging where facilities exist. Check with your 

local council authority for recycling advice.

Spare parts can be ordered from the Special Orders Desk 

at your local Bunnings Warehouse.

 

For further information, or any parts not listed here, visit 
www.ozito.com.au or contact Ozito Customer Service:

 

Australia 1800 069 486

 

New Zealand 0508 069 486

 

E-mail: [email protected]

SPARE PARTS

Cleaning

• Keep the ventilation vents of the air pump clean at all times, if 

possible, prevent foreign matter from entering the vents.

• After each use, blow air through the air pump housing to ensure it is 

free from all dust particles which may build up. Build up of dust particles 

may cause the air pump to overheat and fail.

• If the enclosure of the air pump requires cleaning do not use solvents 

but a moist soft cloth only. Never let any liquid get inside the product; 

never immerse any part of the air pump into a liquid.

Note:

 Ozito Industries will not be responsible for any damage or 

injuries caused by the repair of the air pump by an unauthorised person 

or by mishandling of the product.

Problem

Cause

Solution

The air pump  

does not start

Cord not connected to 

the power

 Connect the power 

cord to a 12V DC 

Car Plug 

On/off switch not in on 

position

Push the on/off 

switch into the on 

position

Adaptors disconnect 

when the pump 

switches on

Loose adaptor

 Ensure the adaptor 

is pushed tightly 

onto the air port

Pump is operating 

but the inflatable 

item is not inflating/

deflating

Some inflatable items 

have a check valve 

that require pinching or 

unscrewing

Pinch or unscrew 

the items valve 

while operating the 

pump

Pump is overheating

While inflating, the 

deflation port is being 

obstructed, restricting 

the flow of the air pump

Ensure the deflation 

port is free of any 

obstructions

While deflating, the 

inflation port is being 

obstructed, restricting 

the flow of the air pump

Ensure the inflation 

port is free of any 

obstructions

MAINTENANCE

TROUBLESHOOTING

WARNING:

 

BEFORE CLEANING OR CARRYING OUT 

ANY MAINTENANCE PROCEDURE, ENSURE THE UNIT 

IS SWITCHED OFF, DISCONNECTED FROM THE POWER 

SUPPLY AND ALLOWED TO COOL DOWN.

IMPORTANT:

 

STORE THE AIR PUMP ONLY IN A 

DRY LOCATION WHICH IS NOT ACCESSIBLE TO 

UNAUTHORISED PERSONS.

A

Amps

Double insulated

Отзывы: