5. CLEANING

MAINTENANCE

WARNING! 

BEFORE CLEANING YOUR AIR 

COMPRESSOR OR CARRYING OUT ANY 

MAINTENANCE PROCEDURE, MAKE SURE THAT IT 

IS DISCONNECTED FROM THE POWER SUPPLY TO 

PREVENT ACCIDENTAL STARTING.

Changing The Oil

The oil should be refilled for the first time after 100 hours of operation. 

Thereafter, the oil should be drained and refilled after every 500 hours 

of service. 

1.  Release any accumulated air pressure from the tank and ensure 

that it is disconnected from the power supply.

2.  Remove the oil drainage 

screw and use a vessel to 

collect the oil from the unit as 

it drains out.

Note: 

if the oil does not drain out 

completely, the compressor may 

be tilted slightly to facilitate this.

3.  Reattach the oil drainage screw.

4.  Remove the breather plug and 

fill the pump with oil up to the 

required level (approximately 

200ml). Ozito compressor 

oil or SAE 15W/40 oil or an 

alternative of the same quality 

is recommended.

5.  Screw the breather plug back 

into place.

6.  Dispose of the old oil in a responsible manner by taking it to 

an old oil drop off point. Check with your local council for more 

information. DO NOT dispose of old oil down the drain.

Cleaning

1.  We recommend that you clean the appliance immediately after you 

use it.

2.  Keep the safety devices free of dirt and dust as much as possible. 

Wipe the equipment with a clean cloth.

3.  Clean the appliance regularly with a damp cloth and some soft 

soap. Do not use cleaning agents or solvents; these may be 

aggressive to the plastic parts in the appliance. Ensure that no 

water can get into the interior of the appliance.

4.  You must disconnect the hose and any spraying tools from the 

compressor before cleaning. Do not clean the compressor with 

water, solvents or the like.

Draining The Pressure Tank

WARNING! 

RELEASE ALL AIR PRESSURE 

FROM THE TANK BEFORE OPENING THE DRAIN 

VALVE. TAKE CARE WHEN DISCHARGING AIR 

THROUGH THE SAFETY VALVE, DRAIN VALVE 

OR AIR OUTLETS. THE DISCHARGED AIR CAN 

CAUSE DUST, STONES, OR ANY OTHER FOREIGN 

PARTICLES TO BE BLOWN THROUGH THE AIR AT 

HIGH PRESSURE.

Air in the compressor tank causes water to accumulate. This must be 

drained off frequently to prevent corrosion and damage to the unit. 

This should be performed after each use and prior to the next 

use.

1.  Turn the drain valve plug 

anti-clockwise (when viewed 

from the bottom of the tank) to 

open it.

2.  Allow all of the water in the tank to drain out.

3.  Replace the drain valve plug and turn it clockwise to tighten it.

Note: 

The tank will not pressurise while the drain valve is open. 

Cleaning The Air Filters

The air filters prevent dust and dirt being drawn in. It is essential 

to clean these filters at least after every 100 hours in service. 

Clogged air filters will decrease the performance of the compressor 

dramatically.

1.  Allow the compressor to run and build up pressurised air in the 

tank. Once the motor has stopped running, turn the compressor off 

and disconnect it from the power supply.

2.  With an air hose and blow gun connected to the regulated pressure 

outlet, turn the pressure regulator until the regulated pressure 

gauge shows a pressure of around 3bar.

3.  Unscrew the wingnut on the 

air filter housing and remove 

the lid.

4.  Remove the filter sponge from 

the housing, tap it and spray 

it with the blow gun to remove 

any dirt. Re-insert it into the 

housing.

5.  Re-attach the lid and wingnut.

MAX.

MIN.

Содержание ACP-4020

Страница 1: ...cified on the tool If the tool shows signs of damage or defects caused by or resulting from abuse accidents or alterations Failure to perform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUST...

Страница 2: ...IN THE MOTOR TO LEAK OUT AND DAMAGE THE UNIT Attaching The Support Foot 1 Place the supporting foot and then a small washer onto the M6 bolt Thread this through the hole in the foot bracket 2 Thread the other small washer and then the spring washer onto the bolt Secure the assembly with the M6 nut Attaching The Wheels 1 Place the M10 bolt through the wheel and a large washer Then slide this throug...

Страница 3: ... automatically start up again when the tank pressure drops to 6bar 2 To switch the compressor off press the on off switch to the 0 position Thermal Overload Protection This Air Compressor is fitted with thermal protection and will shut off to protect the compressor from overheating The compressor may also have shut off due to reaching max cut off pressure If you are unsure use an attached blow gun...

Страница 4: ...ool to one end of an air hose and the air hose to an outlet depending on the tool or application 6 Turn the compressor back on and adjust the regulated pressure to the desired level once the pump has shut off and the compressor has reached cut off pressure 8bar 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00...

Страница 5: ...GAUGE kg cm ON OFF 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 100 125 150 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 100 125 150 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BA...

Страница 6: ...ance 4 You must disconnect the hose and any spraying tools from the compressor before cleaning Do not clean the compressor with water solvents or the like Draining The Pressure Tank WARNING RELEASE ALL AIR PRESSURE FROM THE TANK BEFORE OPENING THE DRAIN VALVE TAKE CARE WHEN DISCHARGING AIR THROUGH THE SAFETY VALVE DRAIN VALVE OR AIR OUTLETS THE DISCHARGED AIR CAN CAUSE DUST STONES OR ANY OTHER FOR...

Страница 7: ...ial Orders Desk at your local Bunnings Warehouse For further information or any parts not listed here visit www ozito com au or contact Ozito Customer Service Australia 1800 069 486 New Zealand 0508 069 486 E mail enquiries ozito com au Storage Transport Pull the mains plug out of the socket and ventilate the appliance and all connected pneumatic tools Switch off the compressor and make sure that ...

Страница 8: ... a power source mains switch power point receptacle outlet etc be sure that the voltage supply is the same as that specified on the nameplate of the tool A power source with a voltage greater than that specified for the tool can result in serious injury to the user as well as damage to the tool If in doubt do not plug in the tool Using a power source with a voltage less than the nameplate rating i...

Отзывы: