page.
32
/
42
32
TROUBLESHOOTING
8.
TROUBLESHOOTING
8.1
ACTIONS TO BE TAKEN DURING FAILURE
1.
Check the machine feeding voltage working with 3 phase of get it checked.
2.
There should be 6 atmospheric pressured air. You can read this value over the regulator-
filter manometer of the machine.
3.
Open the valve board cover of the machine. Check whether there is air leakage or not in air
hoses, air connection elements or valves. Try to correct it if there is an air leakage.
4.
Close the main power switch on the machine and open the cover of the electrical board.
Check whether the two fuses in the board have blown or not. Correct if there is a break in
the cables on the contactors and if there is looseness in the connector screws.
8.2
FAILURE – REASON – SOLUTION TABLE
FAILURE
REASON
SOLUTION TABLE
There is no movement
Electrical failure
Air connection failure
Check the safety power switch.
Check the fuses.
Check the input phases.
Check the air connections.
Check the air pressure on the
conditioner.
Motors are not turning
Electrical failure
Check the safety power switch.
Check the fuses.
Right head motor is turning and
the left head motor is not
turning
Thermic blown
Motor failure
Check the thermic of the left
head.
Replace the motor with the
new one.
Left head is motor turning,
right head motor is not turning
Thermic blown
Motor failure
Check the thermic of the right
head.
Replace the motor with the
new one.
Clamping cylinders do not
clamp
Valve or cylinder failure
Содержание OMRM-133
Страница 1: ...USER MANUAL AUTOMATIC DOUBLE HEAD CUTTING SAW Model No OMRM 133 ...
Страница 40: ...page 39 42 39 CIRCUIT DIAGRAMS AUTO M ATIC DO UBLE HEAD C UTTING M AC HINE 02 02 201 2 ...
Страница 41: ...page 40 42 40 CIRCUIT DIAGRAMS AUTO M ATIC DO UBLE HEAD C UTTING M AC HINE 02 02 201 2 DISPLAY ...