page.
15
/
42
15
PRINCIPLES OF WORK
-
Input X17
ON when thermal relay has overload
-
Input X20
ON when Head № 2 cylinder’s sensor has signal
-
Input X21
ON when “Forward” button pushed
-
Input X22
ON when “Backward” button pushed
-
Input X23
ON when “Fast” button pushed
OUTPUT (Output signals)
-
Output Y0
ON when Head № 2 moves forward
-
Output Y1
ON when Head № 2 moves backward
-
Output Y2
ON when Head № 2 moves forward fast
-
Output Y3
ON when Head № 1 motor is ON
-
Output Y4
ON when Head № 2 motor is ON
-
Output Y5
ON when clamp valve Works
-
Output Y6
ON when Head № 1 valve works
-
Output Y7
ON when cuttıng operation on Head № 1 occurs
-
Output Y10
ON when cuttıng operation on Head № 2 occurs
-
Output Y11
ON when Head № 1 motor lamp is ON
-
Output Y12
ON when Head № 2 motor lamp is ON
-
Output Y13
ON when Head № 2 clamp valve is ON
-
Output Y14
ON when Head № 1 adjusted at 45°
-
Output Y15
ON when Head № 1 adjusted at 90°
-
Output Y16
ON when Head № 2 adjusted at 45°
-
Output Y17
ON when Head № 2 adjusted at 90°
Before the operation starts it is necessary to be convinced of absence people (service staff,
etc.) near to the machine which can receive damages at movement of units of the machine;
the operator should be attentive for the purpose of protection of health of persons which
can be near to it, also it is necessary to warn surround persons about machine operation.
Содержание OMRM-133
Страница 1: ...USER MANUAL AUTOMATIC DOUBLE HEAD CUTTING SAW Model No OMRM 133 ...
Страница 40: ...page 39 42 39 CIRCUIT DIAGRAMS AUTO M ATIC DO UBLE HEAD C UTTING M AC HINE 02 02 201 2 ...
Страница 41: ...page 40 42 40 CIRCUIT DIAGRAMS AUTO M ATIC DO UBLE HEAD C UTTING M AC HINE 02 02 201 2 DISPLAY ...