background image

2 • Oz Charge manual 

 www.ozcharge.com.au

• 

Multi Stage:

1 - Qualification - Battery condition check

2 - Battery rejuvenation (recondition mode)

3 - Soft start charging

4 - Bulk charging

5 - Absorption charging

6 - Equalisation charging

7 - Battery analysis

8 - Float mode 

9 - Long term maintenance pulse charge 

• 

Automatic diagnosis and charge: On power up, the charger will automatically 

diagnose the battery condition and determine if the rejuvenation mode 

(reconditioning) or charge cycle is required.

• 

Patented battery rejuvenation technology:  The charger has a unique and 

patented rejuvenation feature which uses high voltage equalising and peak pulse 

reconditioning to repair sulphated batteries. This feature is fully automatic and 

depends on the internal impedance of the battery and battery voltage.

• 

Can be left on 24/7 to ensure your battery is always maintained and fully 

charged: The battery charger can be left unattended and left permanently 

connected all year round. The intelligent charger will monitor the battery voltage and 

will maintain it at peak performance with a special pulse charge during long term 

maintenance.

• 

Short circuit and reverse polarity protection.

• 

ECO Mode: Ultra low power consumption.

Содержание OC2404M

Страница 1: ...OWNER S MANUAL Model OC2404M AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Страница 2: ......

Страница 3: ...unning cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don...

Страница 4: ...batteryrejuvenationtechnology The charger has a unique and patented rejuvenation feature which uses high voltage equalising and peak pulse reconditioning to repair sulphated batteries This feature is fully automatic and depends on the internal impedance of the battery and battery voltage Canbelefton24 7toensureyourbatteryisalwaysmaintainedandfully charged The battery charger can be left unattended...

Страница 5: ...y SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthecharger frombeingdamagedifthepositiveandnegativecrocodileclipsorringterminals accidentlytoucheachotherwhilethechargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power consumption circuit If AC power is connected and t...

Страница 6: ...re 25 to 85 C Operating Humidity 90 RH Max Size L W H 214mm x 103mm x 55mm Weight 1 1kg Approvals CE UL cUL AS NZS EMC CHARGING INSTRUCTIONS STEP 1 Pre charge check electrolyte level check Check the Battery Electrolyte levels Not required on sealed maintenance free batteries If necessary remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines C...

Страница 7: ...OFF Disconnect the battery charger from the battery charger socket Note Thechargerhasbeendesignedtobeleftturnedonandswitchingthechargeron offtoconnect reconnectisnotnecessary LED STATUS INDICATOR TABLE LED Status Description ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Absor Green Flash ON Flashing during equalisation charging or...

Страница 8: ...attery voltage doesn t reach 22V within 6 hours the safety timer protection will stop the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing 4 Bulk Charging Blue Bulk LED ON Uses the maximum charge output until the battery voltage reaches 28 8 If the battery voltage doesn t reach this within 24 hours the safety timer protection will stop the unit from charging and the R...

Страница 9: ...ated Checkthattherearenoforeign objectsinsidetheXLR connectors CheckthattheXLRplugshave beensecurelyconnected CheckthattheXLRplugshave notbeenforcedtogether incorrectly Movechargertoacoolerarea RefertoLEDIndicatorTable Nocharging current FaultLEDisON Batteryisseverelysulphated Batteryhasadamagedcell ChecktheBatterycondition ageetc Batterymayneed replacement Longcharging time Fulllight doesnot come...

Страница 10: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE ...

Страница 11: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Страница 12: ...OC2404M Owner s Manual Rev 1 0 5 15 Specifications subject to change without notice SAAApproval No GMA 102826 EA 002 ...