background image

6 • Oz Charge manual   

www.ozcharge.com.au

THE CHARGING PROCESS:

1)  Qualification - Battery Condition Check

When the charger is first switched on it checks the battery condition to determine whether the battery 
needs reconditioning. During this qualification process it checks the internal impedance and initial 
voltage of the battery and it will determine how much charge current, if any that the battery will accept. 

2)  Automatic Enhanced Battery Rejuvenation - Blue Bulk LED Flashing Fast

If the initial qualification detected that the battery was in poor condition, the patented rejuvenation 
process will begin automatically. During the rejuvenation process a high voltage equalising and peak 
pulse reconditioning charge is used to repair the sulphated battery. This unique patented feature will 
break down and dissolve the lead-sulphate crystal build up on the battery plates which will extend the 
life of your battery. It can also balance out high concentrations of acid. The equalisation voltage will be 
16V (32V) maximum. If the charging current detected is less than 0.1A after 24 hours, the Rejuvenation 
process will time out.
Manual  Enhanced Rejunvenation Mode
To manually rejuvenate your batteries, simply press and hold the Battery Type button for 3 seconds until 
the Blue Bulk LED flashes rapidly. This mode will last for 24 Hours. To stop rejuvenation mode, press and 
hold the Charge Rate button for 3 seconds until the Blue Bulk LED stops flashing rapidly. Important 
Note:
 Please check your Battery Type and Charge Rate selection to ensure you haven’t accidentally 
changed these settings.

3)  Soft Start Charging - Blue Bulk LED Flashing Slow

Gently charges the battery using a reduced charge output until the battery voltages reaches 11V (22V). If 
the battery voltage doesn’t reach 11V (22V) within 6 hours, the safety timer protection will stop the unit 
from charging and the Red Fault LED and Blue Bulk LED will start flashing.

4)  Bulk Charging - Blue Bulk LED ON

 (Charge Voltage depends on battery type selection)

Uses the maximum selected charge output until the battery voltage reaches the Charge Voltage 
specified for the selected Battery Type.  If the battery voltage doesn’t reach this within 24 hours, the safety 
timer protection will stop the unit from charging and the Red Fault LED will start flashing and the Blue 
Bulk LED will be ON.

5)  Absorption Charging - Green Absorption LED ON

Uses a constant voltage while reducing the charging output current to ensure the battery receives a full 
charge without overcharging the battery. 

6)  Equalisation Charging - Blue Bulk LED and Green Absorption LED both flashing 

A well proven process that carefully overcharges the battery to restore it’s full capacity. The Equalisation 
stage for CALCIUM Battery type selection is automatic. The Equalisation stage for AGM&WET and GEL 
Battery Types only occurs if the initial start voltage is below 11V  (22V).

7)  Battery Analysis - Green Full LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is completed. If the 
battery voltage drops too quickly during the analysis mode, this means the battery is probably faulty.  If 
the battery analysis failed, the Green Full LED flashing.

8)   Float Mode - Full Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is well maintained and 
kept 100% fully charged. Float mode will maintain the battery at a constant 13.6V (27.2V). 

Содержание OC1225U

Страница 1: ...VED RED CONNECTION IN VEHICLE NEGATIVELY EARTHED RED BLACK CONNECTION IN VEHICLE POSITIVELY EARTHED BLACK OWNER S MANUAL Models OC1225U OC2412U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED INCLUDING CLAUSE 21 102 FOR VIBRATION SPECIFICALLY FOR USE IN CARAVANS AND SIMILAR VEHICLES ...

Страница 2: ...rs your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings brace...

Страница 3: ... charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Short circuit and reverse polarity protection Heavy duty and corrosion resistant output connectors Crocodile clips and ring terminals It comes with 2 different kinds o...

Страница 4: ...ED will come on Thispreventsthechargerfrombeingdamaged ifthepositiveandnegativecrocodileclipsortheoptionalringterminalsaccidentlytoucheach otherwhilethechargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is disconnected after 10 seconds the charger will automatically go into an ECO mode Both the selec...

Страница 5: ...V Power Supply Output 13 8VDC 25A Max 27 6VDC 12A Max StartVoltage 2V 4V OperatingTemperature 15 to 50 C 15 to 50 C StorageTemperature 25 to 85 C 25 to 85 C Operating Humidity 90 RH Max 90 RH Max Temp Compensation 25mV C 50mV C Size L W H 279mm x 141mm x 67mm 279mm x 141mm x 67mm Weight 2 kg 2 kg Approvals CE AS NZS EMC CE AS NZS EMC CHARGING INSTRUCTIONS STEP 1 Pre charge check electrolyte level ...

Страница 6: ...codile clip or ring terminal lead to the vehicle s chassis DO NOT connect the Red lead to the carburettor or fuel lines STEP 3 Connect the battery charger to Mains Power 220 240Vac The charger will automatically start when AC power is connected and switched on IMPORTANT Please make sure the correct BatteryType and your desired Charge Rate is selected to suit your battery by pressing the Select But...

Страница 7: ...settings 3 SoftStartCharging BlueBulkLEDFlashingSlow Gentlychargesthebatteryusingareducedchargeoutputuntilthebatteryvoltagesreaches11V 22V If thebatteryvoltagedoesn treach11V 22V within6hours thesafetytimerprotectionwillstoptheunit fromchargingandtheRedFaultLEDandBlueBulkLEDwillstartflashing 4 BulkCharging BlueBulkLEDON ChargeVoltagedependsonbatterytypeselection Usesthemaximumselectedchargeoutputu...

Страница 8: ...pe is selected ChargeRateLED s Green ON Indicates which Charge Rate Charge Mode is selected ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Absor Green Flash ON Flashing during equalisation charging or ON during Absorption charging Bulk Blue Flash ON Fast Flash Rejuvenation Slow Flash Soft Start charging ON Bulk charging Power Suppl...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE Can also be activated manually ...

Страница 10: ... Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Battery Ah capacity too large for the battery charger and it has time out Battery is defective Battery is s...

Страница 11: ...a copy of their receipt for proof of purchase It is recom mended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Страница 12: ...cations subject to change without notice SAAApproval No GMA 102826 EA 004 The optional remote display will suit both the OC1225U and OC2412U For further information please visit www ozcharge com au www ozcharge co nz Optional Remote Display Model OC RDP ...

Отзывы: