3.1
Prior to commissioning
Water reservoir
Ensure there is enough water in the water reservoir. Use water of the same purity as
drinking water. It is recommended that an anti-algae additive is used. For instructions
about using additives see
"Required water purity and the use of additives" on page 13
.
For instructions on filling see
"Filling the water reservoir" on page 14
.
Note
The water reservoir has been carefully positioned by the installer. All
hoses have been installed carefully and without kinks. Do not tamper
with the installation in order to avoid catching or restricting any of the
hoses.
Power supply at the final destination
When the final destination is reached, the CABIN 400 receives its electrical supply via
the 230 Volt mains connection.
Power supply when travelling
When the CABIN 400 is used during the journey to the final destination, the electrical
supply is provided by the 12 Volt battery via a static converter. Even though the unit
consumes very little power, it should be noted that it can flatten the battery. As
standard, the Cabin 400 is fitted with a static converter with an automatic switch-in
function. Should the external 230 V supply be interrupted, the static converter will
automatically switch to battery power.