VZR.248100.000 IG
K-14 Swing gate
Installation Guidelines
12
Figure 4 - Shown appearance of cross-board and location of connectors for
power supply unit, control panel, ACS and security and fire alarm system.
Figure 4
– Appearance of cross-board
In Table 1, the product operation modes for different jumper positions are given.
Таблица 1 – The product operation mode
Jumper positions
Product operation mode
J1 is not installed
Pulse control mode (p. 5.3)
J1 installed
Potential control mode (p. 5.3)
J2 installed
Direction of the leaf opening in anti-panic mode * left/right
J2 is not installed
Direction of the leaf opening in anti-panic mode* changes to
the opposite, relative to the mode with the installed jumper
*
anti-panic mode is automatically switched-off after 20 minutes of switching on.
–J3 jumper is used to enable regular speed of leaf opening and
accelerated by 5 percent.
J3
– not installed: standard opening speed of the gate; installed:
accelerated by 5 percent gate opening.
–J4 jumper is always not installed, it can be used to organize normal
operation of bus of CAN2.0 standard.