Fig.59
CURS MEAS Menu
The description of the
cursor measurement menu
is shown as the following table:
Function Menu
Setting
Description
Type
OFF
Voltage
Time
Switch off the cursor measurement.
Display the voltage measurement cursor and
menu.
Show time measures the cursor and menu.
Source CH1,
CH2
Choose the channel generating the wave form to
which the cursor measurement will be applied.
Delta
Read the difference between cursors.
Cursor 1
Read the position of Cursor 1 (the Time is read
with reference to the horizontal trigger position
and the Voltage is to the ground point).
Cursor 2
Read the position of Cursor 1 (the Time is read
with reference to the horizontal trigger position
and the Voltage is to the ground point).
Cursor Measurement
When carrying out the cursor measurement, the position of Cursor 1 can be adjusted
with the
CURSOR1 (VERTICAL POSITION)
knob of Channel 1, and that of
Cursor 2 can be adjusted with the
CURSOR2 (VERTICAL POSITION)
knob
of
Channel 2.