5.Front Panel Operation
23
Note
:
The Sum of the Deviation and the Carrier Frequency must be less than or equal to the sum
of upper limit of current carrier frequency and 1kHz.
For an External Source, the Deviation is controlled by the voltage Level of the signal
connected to the
Modulation In
connector in the rear panel. +5V corresponds to the
selected Deviation and -5V to the negative selected Deviation.
PM (Phase Modulation)
The modulated waveform consists of two parts: the Carrier Waveform and the
Modulating Waveform. The Carrier Waveform can only be Sine. In PM, the phase of the
Carrier Waveform varies with the instantaneous voltage level of the modulating
waveform. The user interface of the PM is shown as below.
Current Parameter
Carrier
Frequency
Carrier
Amplitude
Carrier Waveform
Carrier Waveform
Modulating Waveform
Load
Phase Deviation
PM Frequency
Mod Type
Mod Shape
Source
Figure 5-14: The User Interface of PM
How to set the parameters of PM
(1)
Press
Mod
function button to enter the Modulation mode.
(2)
Press
F1
to switch Mod Type to PM. If the Carrier Waveform is not Sine, the
system will switch it to Sine automatically.
(3)
Press
button to display the waveform and parameters of the Carrier
Waveform. You can change the parameters, please refer to "
on P11. Press
button again to return to the Modulation mode interface.
(4)
Press
F5
to select the source. If the source is External, use the
Modulation In
connector in the rear panel to input the external signal, then skip ahead to step (6). If
you choose Internal, continue to the steps below.
(5)
Press
F2
to choose Mod Shape, you can choose Sine, Square or Ramp.
(6)
Press
F3
to set PM Frequency. The range is 2 mHz - 20 KHz (Internal source only).
(7)
Press
F4
to set Phase Deviation. The Phase Deviation between the Modulating