background image

LP-GAS CYLINDER INFORMATION:

 

Cylinder Size:  20 Lbs. (9kg)  Capacity: 4.7 Gallons (17.8 Liters).

BEFORE INSTALLATION, BE SURE THE PROPANE TANK IS TURNED OFF.

Turn on the gas to the burner system and test for leaks with soapy water solution.
(Never use an open flame for testing).  If a leak is found, tighten the connector until no leaks are detected.
The hose and burner should be inspected before each use of the appliance.
The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive 
abrasion or wear, or if the hose is damaged.  The replacement hose shall be that specified by the manufacturer.

Page 5

The LP-gas cylinders must be stored outdoors in a well-ventilated area out of the reach of children. Disconnected 
cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage, or any 
other enclosed area.

5.

6.

The cylinder supply system must be arranged for vapor withdrawal.

1.

The LP-gas cylinder(s) to be used must be constructed and marked in accordance with the U.S. Department of
Transportation (D.O.T.) Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for 
Transportation of Dangerous Goods and Commission, CAN/CSA-B339 as applicable.
--Use propane cylinders approved for your area such as “Blue Rhino” or “AmeriGas” with this appliance.  Other 
cylinders may be acceptable for use with the appliance provided they can be mounted to the appliance using the 
cylinder retention devise provided.  (See illustration above.)
--The LP-gas supply cylinder to be used must be provided with a listed overfilling prevention device and with a 
cylinder connection device compatible with the connection for the appliance.

2.

3.

If the appliance is not in use, the gas must be turned off at the supply cylinder. 

The cylinder must be disconnected when the appliance is not in use.

4.

C.

Minimum

 

Clearance

 

to

 

Combustibles

 

(page

 

2).

 

INSTALLATION INFORMATION

CONNECTING THE GAS TO THE FIRE PIT

IMPORTANT

BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY 

INFORMATION CONTAINED IN THIS OWNER'S MANUAL, INCLUDING:

A.

Pre

Installation

 

and

 

Outdoor

 

Fire

 

Pit

 

Preparation

 

Safety

 

Guidelines

 

(page

 

3).

 

B.

Media

 

Installation

 

Guidelines

 

(Page

 

6

8).

Содержание 51-01 Cypress

Страница 1: ...ce instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored within 60 of this unit or any other appliance If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep ...

Страница 2: ...eiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc CAUTION INSTALLATION MODIFICATION AND REPAIR MUST BE DONE BY A CERTIFIED PROFESSIONAL TECHNICIAN or LICENCED PLUMBER FOR OUTDOOR USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WARNING CARBON MONOXIDE POISONING MAY LEAD TO D...

Страница 3: ...mn FOR PROPANE The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches 203 mm water column and the maximum inlet gas supply pressure is 13 inches 330 mm water column DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED G If the Outdoor Fire Pit is connected to Natural Gas its main gas valve must be disconnected from the gas sup...

Страница 4: ...O W Lee Company 1822 E Francis Street Ontario CA 91761 IMPORTANT SAFETY INFORMATION A YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE AREA OF THIS APPLIANCE OPERATING INSTRUCTIONS DO NOT sit or place any part of the body or combustible materials on the Fire Pit surround Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid...

Страница 5: ...ucted and marked in accordance with the U S Department of Transportation D O T Specifications for LP Gas Cylinders or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable Use propane cylinders approved for your area such as Blue Rhino or AmeriGas with this appliance Other cylinders may be acceptable for use with the appliance ...

Страница 6: ...damage If any parts are missing or damaged call your dealer Do not attempt to install the appliance unless all parts are in good condition B Correct installation is crucial to safe performance of your Outdoor Fire Pit C Due to high temperatures the Fire Pit must be located out of traffic areas and away from combustibles CAUTION BURN HAZARD LAVA GRANULES WILL REMAIN HOT FOR SOME TIME AFTER USE YOU ...

Страница 7: ...s of media onto the burner support Spread the media evenly covering the burner CAUTION BURN HAZARD FIRE PIT MEDIA WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING GEM MIRRIORED...

Страница 8: ...HERE MEDIA WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Ceramic Rock Placement See Figure 1 2 and 3 Page 8 Ceramic Sphere Placement See Figure 1 2 3 and 4 Figure 1 Pour the...

Страница 9: ...ll a qualified professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFOIRMATION...

Страница 10: ...ent Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For Propane gas remove the air shutter so that the air intake holes are open Figure 1 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE THE FIELD CONVERSION FIGURE...

Отзывы: