Cover - Important Safety Information
1
Table Of Contents
2
Important Safety Information
Minimum Clearances to Combustibles
2
Pre-Installation & Preparation Guidelines
3
Installation Information
Connecting the Gas to the Fire Pit
5
Certified Media List
6
Glass Media Installation
6
Gem, Mirriored, Tumbled Glass and Ceramic Log Installation
7
Ceramic Rock and Sphere Media Installation
8
Operation Instructions
9
Lighting Instructions
9
Operating Instructions
4
Conversion to a Different Gas Type
10
A.
B.
C.
D.
OUTDOOR FIRE PIT - TABLE OF CONTENTS
IMPORTANT SAFETY INFORMATION
READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.
If not installed and used correctly per these instructions,
this product can cause serious injury and or property damage
.
Be sure you understand all safety precautions and warnings contained in this manual.
CHECK STATE AND LOCAL CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.
If you have any questions, please contact O.W. Lee at (800) 776-9533
Page 2
Clearances to Combustible Construction:
Sidewalls: 60” (1.5 m) from center of unit (Figure 1)
Ceiling: 60” (1.5 m) from top of unit to ceiling or overhang
Flooring: 0” – Can be installed on deck, slab, floor, etc.
CAUTION: INSTALLATION, MODIFICATION AND REPAIR MUST BE DONE BY
A CERTIFIED, PROFESSIONAL TECHNICIAN or LICENCED PLUMBER.
FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER
TO ANY COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.
WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT MODIFY THIS OUTDOOR
FIRE PIT OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.
Any other change may be dangerous. Improper installation or use of your Outdoor Fire Pit can cause serious
injury or death from fire, burns, explosions or carbon monoxide poisoning.
MINIMUM CLEARANCE TO COMBUSTIBLES
The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor
Fire Pit. THERE MUST BE AT LEAST 60” of clearance
from the center of the unit to any combustible sidewalls,
ceilings, or material.
Figure 1
When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF ON THE FIRE PIT and
close the valve on the PROPANE TANK or NATURAL GAS supply.
NOTE
MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE
OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR
OVERHANG
60” (1.5 m)
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
60” (1.5 m)
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION