background image

D.

E.

IMPORTANT SAFETY INFORMATION

A.

Before installing this Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,
garage, or any other enclosed area including recreational vehicles and/or boats.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and 
during all weather conditions. 

B.

CHECK GAS TYPE (natural gas or propane):  The gas supply you intend to use may not be the same as that 
stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If the 

gas supply is different, 

or you wish to change to natural gas, you MUST have the Fire Pit Converted (method 

described on page 8) to the gas type you intend to use, by a qualified, professional technician

.  If you are 

unsure, contact your dealer for assistance.

C.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE 
MAXIMUM.

F.

Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 
pressure loss will occur if the pipe is too small or the run is too long.

Page

 

3

FOR NATURAL GAS: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

5 inches

 (127 

mm) water column and maximum inlet gas supply pressure is 

10 inches

 (254 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS 
EXCEEDED.

G.

If the Outdoor Fire Pit is connected to Natural Gas, its main gas valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5kPa).  

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every 
joint securely.  Do not use pipe joint compound to connect flare fittings.

I.

J.

SAFETY NOTE:  An external on/off valve in the gas line is required for safety when your Outdoor 

Fire Pit is not in use.  It also provides for convenient maintenance and repair.

K.

Casual Fireside Fire Pits are suitable for installation from 0 - 4500 ft. without modification.

H.

If the Outdoor Fire Pit is connected to Natural Gas, it must be isolated from the gas supply piping system by 
closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5kPa).

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  

Any signs of excessive abrasion MUST BE REPLACED.  Contact your local dealer for replacement part 

Location Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  

When installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

M.

Содержание 51-01 Cypress

Страница 1: ...ce instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored within 60 of this unit or any other appliance If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep ...

Страница 2: ...eiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc CAUTION INSTALLATION MODIFICATION AND REPAIR MUST BE DONE BY A CERTIFIED PROFESSIONAL TECHNICIAN or LICENCED PLUMBER FOR OUTDOOR USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WARNING CARBON MONOXIDE POISONING MAY LEAD TO D...

Страница 3: ...mn FOR PROPANE The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches 203 mm water column and the maximum inlet gas supply pressure is 13 inches 330 mm water column DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED G If the Outdoor Fire Pit is connected to Natural Gas its main gas valve must be disconnected from the gas sup...

Страница 4: ...O W Lee Company 1822 E Francis Street Ontario CA 91761 IMPORTANT SAFETY INFORMATION A YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE AREA OF THIS APPLIANCE OPERATING INSTRUCTIONS DO NOT sit or place any part of the body or combustible materials on the Fire Pit surround Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid...

Страница 5: ...ucted and marked in accordance with the U S Department of Transportation D O T Specifications for LP Gas Cylinders or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable Use propane cylinders approved for your area such as Blue Rhino or AmeriGas with this appliance Other cylinders may be acceptable for use with the appliance ...

Страница 6: ...damage If any parts are missing or damaged call your dealer Do not attempt to install the appliance unless all parts are in good condition B Correct installation is crucial to safe performance of your Outdoor Fire Pit C Due to high temperatures the Fire Pit must be located out of traffic areas and away from combustibles CAUTION BURN HAZARD LAVA GRANULES WILL REMAIN HOT FOR SOME TIME AFTER USE YOU ...

Страница 7: ...s of media onto the burner support Spread the media evenly covering the burner CAUTION BURN HAZARD FIRE PIT MEDIA WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING GEM MIRRIORED...

Страница 8: ...HERE MEDIA WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Ceramic Rock Placement See Figure 1 2 and 3 Page 8 Ceramic Sphere Placement See Figure 1 2 3 and 4 Figure 1 Pour the...

Страница 9: ...ll a qualified professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFOIRMATION...

Страница 10: ...ent Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For Propane gas remove the air shutter so that the air intake holes are open Figure 1 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE THE FIELD CONVERSION FIGURE...