Page 4
adapter. Remove adapter, replace
O’rings and gasket, and reinstall adapter.
MODEL C-195-OWI
TORQUE CONVERTER
BREATHER FILTER
The breather filter is located on the left side of the torque converter and covers the oil fill port.
Periodic cleaning and inspection of the breather filter element should be made to prevent the
accumulation of hazardous oil vapors and air pressure within the torque converter housing.
Operation in dusty areas will require more frequent cleaning and inspection.
The filter element may be cleaned with any suitable cleaning solvent.
STRAINER AND ORIFICE ASSEMBLY
The strainer and orifice assembly is located on the end cap of the pressure control valve.
This should be cleaned when the oil filter is cleaned to avoid clogging. If the strainer or orifice
is plugged, the pressure control valve will not operated properly, resulting in sluggish pressure
response to loading and unloading of the torque converter. The torque converter will tend to
overheat and/or dump oil from the circuit.
SUCTION STRAINER
There is a suction strainer located in the bottom of the sump. This strainer is a safety device to
prevent large objects from being drawn into the oil pump and should not ordinarily require
attention. It should, however, be checked in case of low oil pressure.
CHAIN ADJUSTMENT
The circulating pump drive chain is adjusted by loosening the bolts on the oil pump retaining
plate and rotating the pump clockwise. The elliptical hole in the retaining plate prevents
excessive rotation that would shut off suction or discharge ports. When this limit has been
reached a new chain is required.
Содержание C-195-OWI
Страница 12: ...Page 9...