Page 2
MODEL C-195-OWI
TORQUE CONVERTER
MOUNTING TORQUE CONVERTER TO ENGINE
(Continued)
6.
Tighten support feet bolts.
7.
Install an oil drain line from the bottom of the engine flywheel housing to the ½" N.P.T.
hole provided in the torque converter sump.
OPERATION
START UP
The following initial start up procedure should be followed at all times when the fluid elements
and cooler have been drained.
1.
Fill the sump with a recommended oil. (APPROXIMATELY 16 U.S. GALLONS)
Use premium grade oil possessing excellent oxidation resistance, corrosion resistance,
and containing anti-foam inhibitors.
Viscosity - SSU of 150 to 200 at 100
o
F
Viscosity Index in Excess of 100
First Choice:
Premium Grade Turbine Oils
Second Choice:
Torque Fluid TypeC
1
or C
2
Third Choice:
Heavy Duty Motor Oils (10 Wt.)
2.
Start the engine and run at idle speed with the compound clutch disengaged for a period
of five minutes. Check the oil level and add oil as required through the breather-filter
port.
3.
Gradually increase engine speed until operating speed is reached. If the pressure remains
steady and in the operating range, the torque converter is ready for load.
THE OIL SHOULD BE CHECKED FREQUENTLY IN THE FIRST TWO HOUR PERIOD AS
Содержание C-195-OWI
Страница 12: ...Page 9...