Page 3
ANY AIR TRAPPED IN THE
CIRCUIT IS GRADUALLY
ELIMINATED.
MODEL C-195-OWI
TORQUE CONVERTER
LUBRICATION
All internal bearings are automatically pressure lubricated with the working fluid. The throw-out
bearings on units equipped with a throw-out clutch between the torque converter and the engine
require daily greasing.
OIL CHANGE
The oil should be changed and the circulating pump chain tightened (See Page 4) after the first
200 hours of operation of a new torque converter or one that has been overhauled.
The oil filter, breather filter, strainer, and orifice assembly should be cleaned each time the oil is
changed.
Under normal conditions the oil should be changed every 3000 hours or every three months if
the torque converter is operated 24 hours per day. The elements and cooler should be drained
and the sump thoroughly cleaned at this time. The elements are drained by removing the two
plugs in the drive bell. The cooler is drained by removing the plug on the bottom of the unit.
OIL FILTER
THE TORQUE CONVERTER MUST BE SHUT DOWN, PRESSURE AT 0 PSI, AND FILTER
DRAIN COCK OPENED BEFORE REMOVING THE FILTER CAN.
The oil filter is located on the outside of the torque converter housing (left side) on the bottom of
the pressure control valve block. The filter may be removed by removing the hex head bolt from
the center of the cover. Be careful not to damage the O’ring seal. The cartridge can now be
removed for inspection and cleaning. (Replace can and O’ring.)
SPIN-ON FILTER
Carefully remove filter cartridge. Fill new filter with oil and install on adapter hand tight. To
replace O’rings and gasket under the spin-on adapter, remove pipe nipple and allen screw inside