Optional Configurations
12
313294D
Optional Hose Position
Fluid inlet swivels and air quick disconnect fitting point to
rear. If desired, these positions can be changed so
hoses travel downward.
Fluid Hoses
1.
Follow Pressure Relief Procedure, page 10. Also
relieve system pressure and flush both fluid hoses,
see proportioner manual.
2.
Disconnect air hose from quick disconnect (D) and
remove fluid manifold (G).
3.
Disconnect fluid hoses from inlet swivels (A, B).
Remove swivels. Remove plugs from optional inlets
(N).
4.
Apply thread sealant to plugs (42c), elbows (AA),
and male threads of swivels (42e, 42f). Install
elbows (16) in optional inlets (N), facing down.
Install swivels (A, B) in elbows. Be sure to install A
swivel (larger) in A side. Install plugs (42c) where
swivels had been. Torque all parts to 235-245 in-lb
(26.6-27.7 N•m).
5.
Connect appropriate hoses to A and B swivels.
Air Hose
1.
Remove quick disconnect fitting (D) and plug (J).
Reverse positions. Apply thread sealant and torque
to 125-135 in-lb (14-15 N•m).
2.
Attach fluid manifold (G). Connect air. Return gun to
service.
NOTICE
To prevent cross-contamination of gun’s wetted
parts, do not interchange A component (white) and B
component (red) parts.
r_256998_313294_1b
D
G
A (White)
B (Red)
TI2417A
N
42c
AA
42e
N
42f
r_256998_313294_8b
J
r_256998_313294_1b
D
G