Shutdown
313294D
9
7.
Connect quick coupler (D). Turn on air. Open air
valve connected to whip hose. Air valve (K) should
be screwed tight. There is no clean off air to adjust
on the mechanical purge gun.
NOTE:
To use optional air inlet, see Optional Hose Position
on page 12.
8.
Adjust Purge Rod Position, see page 23.
9.
Turn on proportioner.
10. Open B (red fluid) fluid valve (about three half
turns). Then open A (white fluid) fluid valve.
11. Disengage piston safety lock, page 7.
12. Turn RAC tip (65) to spray position.
13. Test spray onto cardboard. Adjust pressure and
temperature to get desired results.
14. Apply layer of lubricant over front of gun and lock
ring, or use gun cover to prevent overspray buildup
and ease disassembly. See Accessories on page
28 to order lubricant and gun cover.
15. Gun is ready to spray.
Shutdown
1.
Follow Pressure Relief Procedure, page 10.
2.
Flush Gun, page 14.
r_256998_313294_1b
D
K
B fluid valve
A fluid valve
r_256998_313294_1b
TI3849A
Disengaged
NOTICE
Air supply is required for gun actuation. Do not dis-
connect gun air supply until fluid pressure is relieved,
page 10.
65
exp1008A