NEO S-Series Library Service Manual
Replacing Parts
10400666-005
©2015-20 Overland-Tandberg
27
5.
Finger-tighten the
blue captive thumbscrews
to secure the power supply.
6.
Attach the supplied
AC power cord
to the new power supply.
7.
Plug the power cord into a
different AC circuit
than the other PSU to operate in
failover mode.
8.
Press the
power button
to power the library back on.
Replace a Power Supply
1.
Use the PSU LEDs to locate the
failed power supply
on the rear of the library.
2.
Verify that all host processes are
idle
and power off the library by depressing the
power
button
on the front panel.
3.
Unplug the
AC power cord
from the PSU being replaced.
4.
Remove the
old PSU
:
a.
Finger-loosen the
three blue captive thumbscrews
on the power supply.
b.
Using the thumbscrews, slowly pull the
power supply
approximately 4 inches (10
cm) out of the library.
c.
While using one hand to support the bottom of the power supply, completely
remove
the
power supply
from the module and set aside.
5.
Install the
replacement PSU
:
a.
Position the
new power supply
onto the alignment rails in the bay.
AC Power Plug