5-10
u
Troubleshooting
F
AULT
S
YMPTOM
C
ODES
(FSC)
2071
Command Timeout
Press Enter to Clear
SOFT fault - Timeout waiting for command
completion.
F
2072
Drive Powerup Error
Power Down Wait 30
Sec, Power Up
HARD fault - drive powerup error. Applies
only to DLT drives.
C, D, G
2073
Drive Config Error
Power Down Wait 30
Sec, Power Up
HARD fault - drive configuration error.
Applies only to DLT drives.
C, D, G
3001
Shuttle Tach Errors
Enter to Reboot or
Power Down to Clear
HARD fault - Excessive elevator tach errors.
The servo has reported an unreachable
velocity.
C, D, G
3002
Picker Tach Errors
Enter to Reboot or
Power Down to Clear
HARD fault - Excessive picker tach errors.
(unreachable velocity).
C, D, G
3003
Gripper Tach Errors
Enter to Reboot or
Power Down to Clear
Excessive gripper tach errors (AIT libraries
only).
C, D, G
3004
Passthru Tach Errors
Enter to Reboot or
Power Down to Clear
Excessive passthru elevator tach errors.
C, D, G
300A
Shuttle Open Tach
Enter to Reboot or
Power Down to Clear
HARD fault - missing tach phase detected on
shuttle servo.
C, D, G
300B
Picker Open Tach
Enter to Reboot or
Power Down to Clear
HARD fault - missing tach phase detected on
picker servo.
C, D, G
300C
Gripper Open Tach
Enter to Reboot or
Power Down to Clear
HARD fault - missing tach phase on gripper
servo.
C, D, G
300D
Passthru Open Tach
Enter to Reboot or
Power Down to Clear
HARD fault - missing tach phase on
Passthru servo.
C, D, G
3010
Picker Retries Excd.
Enter to Reboot or
Power Down to Clear
HARD fault - Picker positioning error.
C, D, G
3011
Slot Fetch Failed
Enter to Reboot or
Power Down to Clear
HARD fault - Fetch from bin failed.
C, D, G
Table 5-2. Fault Symptom Codes
Содержание LXLS10
Страница 1: ......
Страница 4: ...xii u Preface PREFACE...
Страница 8: ...iv TABLE OF CONTENTS CONT D...
Страница 10: ...x LIST OF TABLES CONT D...
Страница 18: ...1 6 u Introduction TAPE CARTRIDGE MAGAZINE...
Страница 86: ...A 4 u Specifications SPECIFICATIONS Declaration of Conformity...
Страница 90: ...Index 2 INDEX...