4.18
1) Remove limit switch chain and sprockets as an assembly.
2) Loosen, but do not remove, cover screws (4) to remove limit
switch cover.
3) Remove limit switch assembly mounting screws (2).
4) Rotate assembly 180 degrees and reassemble in reverse
order.
5) Adjust/reroute hoist interlock cable if needed.
(Hoist models only).
6) Install sprockets and chain in reverse order.
7) Align sprockets and tighten set screws.
8) Reinstall cover.
Some installations may require the reversal of the Limit Switch
Assembly box to facilitate installation.
Limit Switch Box Reversal (Hoist Models Only)
Section 4: Installation
Enclosure Mounting
1) Affix enclosure to wall with appropriate mounting hardware.
2) Route conduit per NFPA and local authority standards.
See typical installation diagram at the beginning of this book as an
example.
Cover Screws
Cover Screws
Mounting Screws
Mounting Screws
Limit Switch Assembly C
over
Hoist Interlock Harness
(Hoist Models Only)
Enclosure Mounting
Tabs (4)
13”
10-5/8”