3.4
Section 3: Critical Installation Information
Counter Doors
600
610
640/641
650/651/652
670
671
Coilaway 24GA.
22GA.
20GA.
18GA.
24GA.
22GA.
20GA.
18GA.
24GA.
22GA.
20GA.
18GA.
22GA.
22GA. / Alum
Alum Steel
RHX
®
1/2
256*
465
403
351
268
247
215
199
169
172**
168**
351**
268**
N/A
ALL*
540
240
RHX
®
1
256*
690
600
523
399
367
320
297
252
172**
168**
480**
399**
N/A
ALL*
700
340
RHX
®
3
256*
N/A
1137
945
867
798
696
645
548
172**
168**
576**
696**
N/A
ALL*
1080
888
Rolling Fire Doors / Fire Shutters
630/631/634
610/620
Note: Door chart represents max. door height of 24ft., over 24ft high consult factory.
* Operator must be wall mounted.
RHX
®
Rolling Steel Door Chart (Sq. Ft.)
Grilles
Rolling Steel Doors
625
Model
HP
416
418
420
422
424
426
430
432
591
592
593
594
596
598
599
Mounting
Type
Max. Door
Weight
(Lbs)
16GA.
Flush
Steel
16GA.
Flush
Steel
Insulated
20GA.
Ribbed
Steel
20GA.
Ribbed
Steel
Insulated
24GA.
Ribbed
Steel
24GA.
Ribbed
Steel
Insulated
Nominal
24GA.
Ribbed
Steel
Nominal
24GA.
Ribbed
Steel
Insulated
Ribbed
Steel
1 5/8"
Ribbed
Steel 2"
Ribbed
Steel
1 3/8"
Raised
Panel
Steel
1 3/8"
20GA.
Flush
Steel
1 5/8"
Ribbed
Steel
1"
Flush
Steel 2"
RHX
®
1/2
SC
1310
330
262
406
330
448
366
326
326
490
448
326
326
380
200
448
326
406
RHX
®
1
SC
1650
448
366
536
448
632
490
326
326
632
584
326
326
501
200
448
326
526
RHX
®
14 RPM -
Direct
Couple
Kit
1
SC
2400
490
406
684
536
792
584
326
326
792
736
326
326
632
200
448
326
526
RHX
®
14 RPM -
Direct
Couple
Kit
3
SC
3696
701
588
1020
821
1020
821
326
326
1164
1020
326
326
888
200
448
326
526
S= Jackshaft, Side Mount, C= Jackshaft, Center Mount
NOTE: Side/Center direct couple kit output speed is 26RPM for 1/2 and 1 HP. For larger doors use 14 RPM output speed direct couple kit on 1HP and 3HP RHX
®
operators.
NOTE: Total door weight, and not the square footage, is the critical factor in selecting the proper operator. Square foot measurments are based on "Square Doors". (Example = 16' X 16')
NOTE: Doors that require special wind loading and wide doors normally require strutting(reinforcement). Strutting doors can significantly increase door weight beyond maximum weight shown. Consult factory
RHX
®
Sectional Door Chart (Sq. Ft.)
Model
HP
Commercial Steel Insulated & Non-Insulated
Thermacore
Aluminum
Door Series ->
511
521
HOIST
416
418
420
422
424
426
430
432
591
592
593
594
596
598
599
Max. Door
Weight
(Lbs)
16GA.
Flush
Steel
16GA.
Flush
Steel
Insulated
20GA.
Ribbed
Steel
20GA.
Ribbed
Steel
Insulated
24GA.
Ribbed
Steel
24GA.
Ribbed
Steel
Insulated
Nominal
24GA.
Ribbed
Steel
Nominal
24GA.
Ribbed
Steel
Insulated
Ribbed
Steel
1 5/8"
Ribbed
Steel 2"
Ribbed
Steel
1 3/8"
Raised
Panel
Steel
1 3/8"
20GA.
Flush
Steel
1 5/8"
Ribbed
Steel
1"
Flush
Steel 2"
RHX
®
1/2
1310
330
262
406
330
448
366
326
326
490
448
326
326
380
200
448
326
406
RHX
®
1
1650
448
366
536
448
632
490
326
326
632
584
326
326
501
200
448
326
526
NOTE: Total door weight, and not the square footage, is the critical factor in selecting the proper operator. Square foot measurments are based on "Square Doors". (Example = 16' X 16')
NOTE: Doors that require special wind loading and wide doors normally require strutting(reinforcement). Strutting doors can significantly increase door weight beyond maximum weight shown. Consult factory
RHX
®Trolley
Sectional Door Chart (Sq. Ft.)
Model
HP
Commercial Steel Insulated & Non-Insulated
Thermacore
Aluminum
511