D-583-2N-E
28
10.3 List of Parameters That Can Be Reconfigured
Table 0.
Parameter
Code Default Setting
Initial
Value
Description
Example of Setup or Remarks
Meter factor
F
Depends
on the
specification.
.0000-2
- Meter factor
(Unit: [
£
/Pulse])
- Setting range:
0.9999-9 to 9.9999E7
Ex.: Given meter factor 9.98L/P
to change the indicated flowrate
to read in [m
3
]
→
If hardware scaler DIV switch is set
at /0, then
9.980 x 0
-3
[m
3
/p]
F=
Hardware scaling (/0)
= 9.980 x 0
-2
[m
3
/P]
Therefore, set to "F9.980 - 2" (m
3
/P)
(Note )
Conversion
factor
H
.0000E0
.0000E0
- Unit conversion factor
(Unit: [
£
/L])
r
: Unit after conversion
(without conversion
r
:=
£
)
- Setting range:
0.9999 to 99.9999E7
To change units of total flow and
instant. flowrate to any units desired.
(If conversion is not desired, then
H.0000E0)
Ex.: At .5kg per L, change the
flowrate to read in kg.
→
Conversion factor is .5 [kg/L]
(=.5000 x 0
-0
[kg/L]).
Therefore, set to "H.5000E0"(kg/L).
(Notes 2 and 3)
Pulse weight
Pu
Depends
on the
specification.
.00E0
- Weight of factored pulse
output (Unit: [
r
/Pulse])
- Setting range:
0.99-9 to 9.99E7
An invalid parameter in this instrument.
Do not change the setting.
Indicated
unit of
registration
Un
m
3
L
- Unit indicated below LCD
Choose one from "L, kL, m
3
, g, kg, t,
(normal), and none." (This setting
process only changes indicted unit;
it by no means changes calculation
process.
Decimal
point in inst.
flowrate
bP
Depends
on the
specification.
0
- Decimal point in
instantaneous flowrate b1
- Setting range: 0,,2
Ex.: To change the indicated resolution
in instant. flowrate from 1L/h to
0.L/h (= one place below decimal
point)
→
Set to "bP .".
Decimal
point in total
flow
SP
Depends
on the
specification.
0
- Decimal point in accum.
total and resettable total
flow
- Setting range: 0, , 2, 3
Ex.: To change the indicated resolution
in total flowrate from 1L/h to 0.01L/
h (= 2 places below decimal point)
→
Set to "bP .2".
Sampling
time
At
5
5
- Upper limit in instantaneous
flowrte sampling
(Unit: [sec])
- Setting range: to 999
If flowrate pulses fail to arrive for a
period At [sec], the instantaneous
flowrate shows 0.
Sample cycle
number
A
Depends
on the
specification.
4
- Count of sampling
- Setting range: to 999
Instantaneous flowrate is determined
by measuring the time for incoming
flowrate pulses A times. If the spread of
instant. Flowrate indicated is too great,
selecting a larger A eases the problem.
NOTES: . Setting the meter factor (F) indicates hardware scaling (DIV switch: /, /0, or /00).
2. Following a change in conversion factor (H), other parameters, such as pulse weight (Pu) and indicated unit of
measurement (Un), must also be adjusted to match the new unit.
3. Be sure to select a value that satisfies the formula of
F×H
2
≦
Pu
≦
F x H x 0000.