![Oval EX DELTA II Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/oval/ex-delta-ii/ex-delta-ii_instructions-manual_1662161014.webp)
D-583-2N-E
4
Fig. 6.5
6.3.2 Installation Procedure
Install the meter in the following manner:
() The meter probe body is provided with blind
caps. Be sure to remove them before you install.
(2) Determine the location by the flow direction
arrow mark and the center mark (V-groove) on
the shaft assembly (02).
(3) Be sure to install the gasket.
CAUTION:
1. Do not forget to install the gasket in
place and tighten bolts.
2. A leak test should be conducted before
commencing operation.
6.4 Installation, Hottap Type
6.4.1 Part Names
V-GROOVE MARK
(CENTER MARK)
PIPE
PROBE BODY
GASKET
BOLT
Fig. 6.4
DRIVE
UNIT
HANDWHEEL (PROBE GOES UP OR DOWN AS YOU
TURN IN OR OUT.)
MATCH MARK B (INDICATES THE POSITION THE
PROBE FULLY RAISED AT.)
MATCH MARK A (INDICATES THE POSITION THE
PROBE FULLY INSERTED AT.)
STUD
GLAND PACKING
SCREW AXIS
GATE VALVE
FLOW
DIRECTION
GUIDE
GASKETS
PACKING RETAINER
COVER
RETAINING RING
SHORT PIPE
(WITH VENT VALVE)
MOUNTING
NOZZLE
HOLD-DOWN DISC (PREVENTS NOISES CAUSED BY
LINE OSCILLATION.)
CAUTION: CARE SHOULD
BE TAKEN IN
THE PHYSICAL
ORIENTATION.
PROBE (FLOWRATE SENSING ASSEMBLY, CONSISTS
OF 2” BODY, BLUFF BODY AND SENSOR.)
Содержание EX DELTA II
Страница 49: ...D 583 2N E 49...