![Oval EX DELTA II Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/oval/ex-delta-ii/ex-delta-ii_instructions-manual_1662161018.webp)
D-583-2N-E
8
HEX SOC. HEAD
SCEW
SENSOR
LEADS
TURN
SHIELD
STRIP
HEX SOCKET HEAD SCREW
90°
6.10 How to Change Preamplifier
Orientation
The preamplifier can be oriented to the desired
direction in 90° steps as shown in Fig. 6..
NOTE: To change the orientation, hex key (JIS
B 4648), nominal size 4, is required. The
preamplifier can be rotated by loosening
its four hex socket head screws, but be
sure to disconnect sensor leads before
attempting to rotate it.
CAUTION: Turning the preamplifier
with sensor leads in place
may damage the sensor.
Procedure
Refer to Section 4, "EXPLODED VIEW AND PARTS
LIST" on pages 37 and 38.
() Turn off power on the display board (see Fig. 6.7
on page 9).
(2) Remove the terminal box cover (Fig. 6.2).
(3) Separate the shield strip (Fig. 6.3).
(4) Disconnect sensor leads from the terminal block.
(5) Loosen a total of four hex socket head screws
securing the preamplifier's neck (Fig. 6.14).
(6) Turn the preamplifier to the desired direction,
exercising care not to force the sensor leads.
(7) When the preamplifier orientation has been
established, assemble in the reverse order of
removal.
Fig. 6.2
Fig. 6.
Fig. 6.3
Fig. 6.4
COVER
Содержание EX DELTA II