E-216-5N-E
18
(2) Temporary stop operation
If you press STOP button, SV/MV output will be turned OFF and the operation will be temporarily stopped. PUMP
output will be stopped after delay timer.
If you press START button, the operation will be restarted.
If the operation is temporarily stopped at upper limit flow rate, both of SV and MV will be turned ON at the restart
and the flow rate will reach the upper limit flow rate (not becomes 2-stage open).
If the operation is temporarily stopped at restricted flow rate, only SV will be turned at the restart and the flow rate
will reach the restricted flow rate.
START button
STOP button
RUN lamp
Pump control
signal
PUMP lamp
SV: restricted flow
rate signal
SV lamp
MV: upper limit flow
rate signal
MV lamp
Batch
completion
signal
END lamp
Flow rate
Time
Forecasted
overrun quantity*
Completion
monitoring time
setting value*
Terminal
setting value*
*Parameter setting
Initial
setting value*
Batch setting quantity*
Pump output delay timer
Pump output delay timer
Blinks
Fig. 8.4