LEAK TESTING
NEVER USE A NAKED FLAME TO CHECK FOR LEAKS.
NEVER LEAK TEST WHILE SMOKING.
The gas connections on this appliance are leak tested at the factory prior to
shipment.
This appliance needs to be periodically checked for leaks and an immediate check is
required if the smell of gas is detected.
Make a soap solution using 1 part of liquid dish-washing soap to 3 parts water. The
soap solution can be applied with a soap bottle, brush, or rag to the leak tested points
shown in the figure above.
The valve of the gas cylinder should be in the OFF position at this point of the leak test.
Once the soapy solution is applied to the gas connections, the valve of the gas cylinder
needs to be turned to the ON position.
Soap bubbles will begin to form in the soapy solution if a leak is present.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas
supply on and recheck.
OPERATING INSTRUCTIONS
BEFORE FIRST USE AND AFTER EVERY GAS CYLINDER CHANGE, GAS DELIVERY
SYSTEM MUST BE PURGED OF AIR BEFORE IGNITING! TO DO THIS, TURN THE
CONTROL KNOB ANTI-CLOCKWISE TO THE PILOT SETTING. PRESS KNOB IN AND
HOLD FOR 3 MINUTES BEFORE ATTEMPTING IGNITION.
TO LIGHT THE PILOT
Check all connections prior to each use.
Turn on main gas supply at source.
Press to turn control knob anti-clockwise to PILOT, see right photo.
Hold knob depressed, press IGNITION button repeatedly until pilot flame is lit, then
continue to hold the knob depressed for 10 seconds until the pilot remains it after
releasing knob.
If pilot fails to ignite or alight, press to turn knob clockwise to OFF and
repeat.
OFF
PILOT
IGNITION
HIGH
LOW
Leak Test Point
①
②
③
④
T O LIGHT THE PATIO HEATER
The pilot should be lit and the knob set to
PILOT.
Hold knob depressed gently and turn anti-
clockwise to HIGH.
When mesh glows lit, turn knob clockwise from
HIGH to LOW as needed.
Note: The burner may be noisy when initially
turned on. To eliminate excessive noise from the
burner, turn the control knob to the pilot position.
Then turn the knob to the level of heat desired.
RE-LIGHTING
Turn Control Knob to OFF.
Wait at least 5 minutes, to let gas dissipate,
before attempting to re-light pilot.
Repeat the “Lighting” steps.
TO EXTINGUISH
Hold knob depressed & turn the knob clockwise
to 'OFF'
Close the valve of the gas cylinder or the
regulator after use.
Close the gas bottle and allow this appliance to
cool before moving the appliance.
Note: After use, some discoloration of the emitter
screen is normal. Close regulator after use, allow
the appliance to cool before moving.