background image

1

 

Outdoor Lifestyles by Hearth & Home Technologies  •  Palazzo Installation Manual  •  4082-311 Rev. A  •  06/08/15 

Installation Manual

Installation and Appliance Setup

INSTALLER:  Leave this manual with party responsible for use and operation.

OwNER:  Retain this manual for future reference.

NOTICE: DO NOT discard this manual!

Models:

ODPALG-48

ODPALGST-48

DANGER

If you smell gas:

1. Shut off gas to the appliance.

2. Extinguish any open flame.

3. If odor continues, keep away from the 

appliance and immediately call your gas 

supplier or fire department.

wARNING: For Outdoor Use Only.

wARNING

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.
An LP-cylinder not connected for use shall not 

be stored in the vicinity of this or any other 

appliance.

wARNING: 

Improper installation, adjustment, 

alteration, service or maintenance can cause injury or property 

damage. Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this 

equipment.

wARNING! 

Risk of Fire!

Do not install glass doors on this fireplace. 

Glass doors could cause overheating of 

adjacent structures.

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide 

which has no odor.

Using it in an enclosed space can kill you.

Never use this appliance in an enclosed space 

such as a camper, tent or home.

DANGER

Содержание DPALG-48

Страница 1: ...tore or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before ...

Страница 2: ...onsiderations 5 B Tools and Supplies Needed 5 C Inspect Appliance and Components 6 3 Framing and Clearances A Appliance Decorative Front Dimension Diagrams 7 B Clearances to Combustibles 9 C Vent Termination Minimum Clearances 12 D Hearth Extension Floor Protection 13 E Stand Alone Installation 13 F Built in Installation 13 G Moisture Resistance 13 4 Appliance Preparation A Securing and Leveling A...

Страница 3: ...for fuel type ___________________________ Was a conversion performed ___________________________ Leak check performed and inlet pressure verified ___________________________ Finishing Section 7 Pg 22 24 Combustible materials not installed in non combustible areas ___________________________ Verified all clearances meet installation manual requirements ___________________________ Mantels and wall pro...

Страница 4: ... interrupter protection in compliance with the applicable electrical codes G Fuel This appliance must not be used to burn solid fuel NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada 1 Product Specific and Important Safety Info...

Страница 5: ...Consult the authorities having jurisdiction over restrictions installation inspec tion and permits Before installing determine the following Where the appliance is to be installed Clearance to side walls Location of indoor appliance terminations air inlets gas meters etc Doors Location of the fireplace to a door that swings open to ensure it does not interfere with the fireplace when opened Window...

Страница 6: ...ty and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged incomplete or substitute components Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Techno...

Страница 7: ... Rev A 06 08 15 3 Framing and Clearances A Appliance Dimension Diagrams Dimensions are actual appliance dimensions Use for reference only For framing dimensions and clearances refer to Figure 3 3 and Figure 3 4 Figure 3 1 Appliance Dimensions ODPALG 48 ODPALG 48 Gas Electric Connections ...

Страница 8: ...8 Outdoor Lifestyles by Hearth Home Technologies Palazzo Installation Manual 4082 311 Rev A 06 08 15 Figure 3 2 Appliance Dimensions ODPALGST 48 ODPALGST 48 Gas Electric Connections ...

Страница 9: ...y cause flames to reach out in front Keep furniture draperies and other combustibles away Locate the appliance away from traffic areas Clean up fallen leaves branches and other combus tible materials before using the appliance See Figure 3 3 3 4 3 5 for required clearances Only install on wood or solid noncombustible surfaces extending full width and depth to prevent damage WARNING Risk of Fire Ma...

Страница 10: ...4 mm from appliance front 1 in 25 mm Note For actual appliance dimensions refer to Section 3 A Figure 3 3 Appliance Locations and Framing Dimensions ODPALG 48 Notice Vinyl siding must not be placed between the appliance opening and the ceiling overhang Notice Flash the perimeter of the appliance corners and the appliance face in a manner consistent with regional practices as required to prevent wa...

Страница 11: ... required to prevent water penetration around the appliance or manage water that may penetrate the appliance See Section 3 F for more information regarding wall and enclosure construction ODPALGST 48 SEE THROUGH NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design pref...

Страница 12: ...earances Note 2 Appliance in an alcove space spaces open only on one side and with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be a 3 ft minimum between terminations or between the fireplace and termination 2 All mechanical air intakes within 10 ft of a termination must be a minimum of 3 ft below the fireplace hood 3 All gravity ai...

Страница 13: ...stallation When this appliance is installed into a wall we recom mend that the wall be an exterior wall system See framing measurements in Figure 3 3 and 3 4 You must maintain 1 in 25mm air space at the back and sides See Figures 3 3 and 3 4 The header must not be placed below the top of the top standoffs Noncombustible wall sheathing material is required from bottom of appliance opening to ceilin...

Страница 14: ...Flash the appliance in a manner consistent with regional practices to prevent water penetration around the appliance Due to elevated temperatures across the top of the appliance metal flashing and high temperature sealant must be used Adhesive polymeric flashing materials may melt For brick stone stucco and similar construction weep screeds should be installed per regional codes See Section 3 F an...

Страница 15: ...Fault Circuit Interrupt protected circuit breaker A Wiring Requirements B IntelliFire Pilot Ignition System Wiring Wire the appliance junction box to 110 120 VAC for proper operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched circuit Incorrect wiring will override IPI safety lockout This appliance supplied standard with Intel...

Страница 16: ...h hole provided on the left side of the appliance Wire Assemble Junction Box See Figure 5 4 Grounding connection to box if box has a grounding terminal Wire connector Junction box LINE cable brings power from the GFCI Circuit Outlet Figure 5 4 Wiring Reinstall Junction Box Mounting Bracket removed in Step 2 See Figure 5 5 Plug in transformer and power supply Junction Box Valve Cover Box Figure 5 5...

Страница 17: ...ACTUATOR SWITCH GREEN LED SWITCH BLUE LED SWITCH 12 PIN CONNECTOR RED BROWN PURPLE BLUE WHITE TAN GREY PINK YELLOW ORANGE GREEN BLACK 12 PIN CONNECTOR 12V DC ACTUATOR To Junction Box LED WIRE HARNESS LED LIGHT STRIPS WIRE HARNESS ORANGE GREEN 12V POWER SUPPLY GAS VALVE CONTROL MODULE 3V AC POWER SUPPLY PILOT ASSEMBLY ORANGE WHITE BROWN WIRES RED BLACK WIRES NOT USED LED WIRE HARNESS WIRE HARNESS W...

Страница 18: ...ng materials being installed See Figure 5 8 NOTE Supplied wire allows for control assembly to be mounted up to 8 ft from appliance 15 ft control wire extension kits are available ODPALG WH15 if needed A maximum of two extension kits 30 ft can be used The cover is designed to protect the switch during the installation of finishing materials as well as to ensure the clearance necessary for future se...

Страница 19: ... appliance Follow local codes Verify inlet pressures Verify minimum pressures when other household gas appliances are operating Install regulator upstream of valve if line pressure is greater than 1 2 psig 6 Gas Information Gas Pressure Natural Gas Propane Minimum inlet pressure 5 0 in w c 11 0 in w c Maximum inlet pressure 10 0 in w c 13 0 in w c Manifold pressure 3 5 in w c 10 0 in w c Fire Risk...

Страница 20: ... non corrosive commercially available leak check solution DO NOT use open flame Fittings and connections could have loos ened during shipping and handling Valve Control Box Gas Electric Pass Throughs Manual Shutoff Valve Junction Box Cover Plate Figure 6 1 Lower Compartment D Valve Access The valve and controls are located in the appliance con trol box See Figure 6 2 Prior to finishing materials T...

Страница 21: ...Check with your local gas utility to determine proper orifice size See conversion kit for instructions on how to change main burner orifice LPK ODPALG 48 Remove screws securing control box upper access panel Remove control box upper access panel See Figure 6 6 After finishing Once finishing materials are added to the face of the ap pliance the control box and controls MUST be accessed through the ...

Страница 22: ...ions for mantels or other combustible projections above the appliance open ing WARNING Risk of Fire DO NOT apply combustible ma terials beyond the minimum clearances Comply with all minimum clearances to combustibles as specified in this manual Overlapping materials could ignite Any instal lation outside the scope as stated in this manual please contact your authorized HHT dealer prior to installa...

Страница 23: ...06 08 15 50 in minimum to ceiling 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Firebox Opening Figure 7 3 Minimum Vertical and Maximum Horizontal Mantel Dimensions For Combustible Materials Note All measurements in inches Mantel Projections ...

Страница 24: ...peratures 3 Since every home has unique air flow characteristics and maximum allowable operating temperatures can vary from manufacturer to manufacturer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers maximum allowable operating temperatures identified ...

Страница 25: ...sawdust that may have accumulated inside the firebox C Optional Accessories Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with this appliance Using non listed accessories could result in a safety hazard and will v...

Страница 26: ...ODPALG WH15 Media Kits Media Ebony 48 Media Cobalt 48 Media Red 48 Media Amber 48 Printed in U S A Copyright 2014 Outdoor Lifestyles a brand of Hearth Home Technologies 7571 215th Street West Lakeville MN 55044 www hearthnhome com Please contact your Outdoor Lifestyles dealer with any questions or concerns For the location of your nearest Outdoor Lifestyles dealer please visit www hearthnhome com ...

Отзывы: