outdoorrooms.com
9
OPERATING INSTRUCTIONS
IMPORTANT
Before operating your DENBR-1242, ensure all gas connections are
properly tightened and thoroughly leak checked. Refer to the Crystal Fire
®
Plus manual for information on proper leak checking and other critical
safety information.
5.
!
!
!
!
FIRE OR EXPLOSION HAZARD
If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
Verify control valve is in OFF position. If operating on a self-contained propane
cylinder, ensure cylinder valve is CLOSED. If operating on a hard-piped system,
ensure main gas supply shut-off valve and all other valves in gas system are
OPEN.
If operating on a self-contained propane cylinder, slowly open cylinder valve.
Press and hold sparker button. Verify an audible and visible spark is present
within the ignition wind guard.
Gently press and turn control knob to LOW/IGNITION position. Fully depress
control knob and hold for 3-5 seconds. Burner should ignite and continue to
operate when control knob is released.
If burner does not light or remain lit after 20 seconds of attempting ignition, turn
control valve to OFF position and wait 5 minutes to allow gas to dissipate before
attempting ignition again.
DO NOT ATTEMPT TO LIGHT BURNER IF YOU SMELL
GAS.
With burner lit and operating, the flame height can be adjusted between LOW
and HIGH at any time.
WARNING
OFF
LOW/
IGNITION
HIGH
PUSH AND HOLD
TO IGNITE
DEPRESS SPARKER
BUTTON
SEE DETAIL B
LOOK FOR SPARK
HERE
OFF
LOW/
IGNITION
HIGH
PRESS AND HOLD
SPARKER BUTTON
ROTATE COUNTER-CLOCKWISE
TO LOW AND SLOWLY DEPRESS
HOLD KNOB IN FOR 3-5 SECONDS