INSTALLATION OF THE FRONT PANEL
1. Adjust the panel to the housing of the indoor unit by matching the position of the swing flap motor of
the panel to the piping position of the housing. See image below.
2. Install the panel on the housing temporarily. When installing, hang the latches on the hooks located on
the opposite side of the panel swing flap motor (2 positions).
3. Hang the remaining 2 latches to the hooks on the sides of the indoor unit.
NOTE
:
Be careful not to let the swing motor lead wire get caught in the sealing material.
4. Screw the 4 hexagon head screws under the latches in about 15 mm (the panel will rise).
5. Adjust the panel by turning it toward the direction pointed by the arrow as shown.
6. Tighten the screws until the thickness of the sealing material between panel and indoor unit reduced
to 5-8 mm.
2
3
3
4
5
6
Latch
Hook
Piping position
Swing flap motor
Indoor unit
Ceiling
Air outlet vent
Decoration panel
Sealing material
5 mm to 8 mm