6
• The appliance shall be installed in accordance with national wiring regulations.
• Installation must be performed in accordance with the requirement of NEC and CEC by a qualified
person only.
• The heat pump is a first class electric appliance. It must be properly grounded with specialized groun-
ding device by a qualified person. Please make sure it is always properly grounded, otherwise it may
cause electric shock.
• The yellow-green wire in the appliance is the grounding wire, which can’t be used for other purposes.
• The grounding resistance should comply with national electric safety regulations.
• All wires of indoor unit and outdoor unit should be connected by a qualified person.
• If the length of power connection wire is insufficient, please contact the dealer for a new one. Do not
extend the wire yourself.
• After the electrical installation, take an electric leakage test.
WARNING
Location
• If you need to relocate the appliance to another place, only a qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
• Select a location which is out of reach for children and far away from animals or plants. If it is unavoi-
dable, please add a fence around the outdoor unit for safety purpose.
• The location should be able to withstand the weight of the unit. Otherwise, the unit will fall and it may
cause injury or death.
• Instructions for installation and use of this product are provided by the manufacturer.
WORKING TEMPERATURE RANGE
Indoor side state
Outdoor side state
Dry bulb temp.
°C (°F)
Wet bulb temp.
°C (°F)
Dry bulb temp.
°C (°F)
Wet bulb temp.
°C (°F)
Rated cooling
27 (80)
19 (67)
35 (95)
24 (75)
Max. cooling
27 (80)
19 (67)
46 (115)
24 (75)
Min. cooling
19 (67)
14 (57)
19 (67)
14 (57)
Rated heating
21 (70)
16 (60)
8 (47)
6 (43)
Max. heating
27 (80)
–
24 (75)
18 (65)
Low ambient heating
21 (70)
16 (60)
-15 (5)
-16 (3)