CAUTION
Signs of wear and tear on the product components
Falling due to damage or malfunction of the product.
►
Regular service inspections (maintenance) are mandatory in the interest of patient safety and in order to main
tain operating reliability and protect the warranty.
CAUTION
Use of unapproved accessories
>
Falling due to product malfunction as a result of reduced interference resistance.
>
Interference of other electronic devices due to increased emissions.
►
Use the product only in combination with the accessories, signal converters and cables listed in the sections
"Scope of delivery" (Scope of delivery) and "Accessories" (Accessories).
NOTICE
Improper product care
Damage to the product due to the use of incorrect cleaning agents.
►
Only clean the product with a damp cloth and mild soap (e.g. 453H10=1-N Ottobock DermaClean).
NOTICE
Mechanical damage to the product
Change in or loss of functionality due to damage.
►
Use caution when working with the product.
►
If the product is damaged, check it for proper function and readiness for use.
►
In case of changes in or loss of functionality, do not continue using the product (see "Signs of changes in or
loss of functionality during use" in this section).
►
Take any necessary measures (e.g. repair, replacement, inspection by the manufacturer's customer service,
etc.).
INFORMATION
When exoprosthetic components are used, the use of control functions which are performed hydraulically or
movement of the component in the footshell can cause movement noise. This kind of noise is normal and unavoid
able. It generally does not cause any problems. If movement noise increases noticeably during the lifecycle of the
component, the component should be inspected by an authorised Ottobock Service Centre immediately.
Signs of changes in or loss of functionality during use
Decreased forefoot resistance or changes in roll-over behaviour are noticeable indications of loss of functionality.
INFORMATION
Cybersecurity
►
Keep your operating system up to date and always install any available security updates.
►
Protect your computer from unauthorised access (e.g., by using virus scans, password protection etc.).
►
Do not use unsecured networks.
►
Please contact the manufacturer if you suspect cybersecurity problems.
INFORMATION
Before mounting the component on the tube adapter, make a note of the serial number of the component. It is
found next to the pyramid on the spherical cap (Design).
The serial number is required to connect to the adjustment software and the Cockpit app and must be entered in
the prosthesis passport.
INFORMATION
The charge level cannot be displayed during the charging process.
15
1B1-2=* Meridium
Safety