Technical Data
13
DTX-2200-3000 AC/DC
6 Technical
Data
The general technical data of the system are summarized in Table1.
Table1
Model
DTX-2000 AC/DC
DTX-3000 AC/DC
TIG
MMA
TIG
MMA
Power supply 50/60 Hz
V
1~ 230 ±20%
3~ 400 ±20%
Power supply: Z
max
Ω
(*)
0,092
Input power @ I
2
Max
kVA
6,5
7,0
9,6
Delayed fuse (I
2
@ 100%)
A
16
10
Power factor / cos
φ
0,99/0,99
0,95/0,99
Efficiency degree
η
0,77
0,76
0,81
Open circuit voltage
V
100
100
Current range
A
5-220
10-180
5-300
10-250
Duty cycle @ 100% (40°C)
A
140
120
210
190
Duty cycle @ 60% (40°C)
A
180
150
250
220
Duty cycle @ X% (40°C)
A
220
(30%)
180
(30%)
300
(35%)
250
(40%)
Usable electrodes
mm
1,2-2,4
1,6-4,0
1,2-4,0
1,6-5,0
Standards
IEC 60974-1 • IEC 60974-3 • IEC 60974-10
Protection class
IP 23 S
IP 23 S
Insulation class
F
F
Dimensions
mm
465 - 390 - 185
495 - 390 - 185
Weight
kg
15,
19
IMPORTANT:
These systems, tested in accordance with the requirements of the EN/IEC 61000-3-3 standard, satisfy the
requirements laid down by the EN/ IEC 61000-3-11 standard.
DTX-2200 TIG
(*) This equipment meets the requirements laid down in the EN/IEC 61000-3-12 standard on harmonic currents.
DTX-2600 TIG
This equipment complies with EN/IEC 61000-3-12 provided that the maximum permissible system impedance Z
max
is less
than or equal to 0,092 at the interface point between the user’s supply and the public system. It is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with maximum permissible system impedance Z
max
less than or equal to 0,092.
Содержание DTX-202 TIG
Страница 1: ...DTX 2200 AC DC DTX 3000 AC DC User Manual ...
Страница 69: ...Wiring diagram DTX 2200AC DC 69 DTX 2200 3000 AC DC ...
Страница 70: ...Wiring diagram DTX 2200 AC DC 70 DTX 2200 3000 AC DC ...
Страница 71: ...Wiring diagram DTX 3000 AC DC 71 DTX 2200 3000 AC DC ...
Страница 72: ...Wiring diagram DTX 3000 AC DC 72 DTX 2200 3000 AC DC ...