background image

Össur Americas

Össur Nordic

Össur Europe BV – Italy

27051 Towne Centre Drive

P.O. Box 67

Via Baroaldi, 29

Foothill Ranch, CA 92610, USA

751 03 Uppsala, Sweden

40054 Budrio, Italy

Tel: +1 (949) 382 3883

Tel: +46 1818 2200

Tel: +39 05169 20852

Tel: +1 800 233 6263

Fax: +46 1818 2218

Fax: +39 05169 22977

Fax: +1 800 831 3160

[email protected]

[email protected]

[email protected]

Össur Iberia S.L.U

Össur APAC

Össur Canada

Calle Caléndula, 93 -

2F, W16 B

2150 – 6900 Graybar Road

Miniparc III

No. 1801 Hongmei Road

Richmond, BC

Edificio E, Despacho M18

200233, Shanghai, China

V6W OA5 , Canada

28109 El Soto de la Moraleja,

Tel: +86 21 6127 1707

Tel: +1 604 241 8152

Alcobendas

Fax: +86 21 6127 1799

Fax: +1 866 441 3880

Madrid – España

[email protected]

Tel: 00 800 3539 3668

Össur Europe BV

Fax: 00 800 3539 3299

Össur Australia

De Schakel 70

[email protected]

26 Ross Street,

5651 GH Eindhoven

[email protected]

North Parramatta

The Netherlands

NSW 2151 Australia

Tel: +800 3539 3668

Össur UK Ltd

Tel: +61 2 88382800

Tel: +31 499 462840

Unit No 1

Fax: +61 2 96305310

Fax: +31 499 462841

S:Park

[email protected]

[email protected]

Hamilton Road

Stockport SK1 2AE, UK

Össur Deutschland GmbH

Tel: +44 (0) 8450 065 065

Augustinusstrasse 11A

Fax: +44 (0)161 475 6321

50226 Frechen

[email protected]

Deutschland

Tel: +49 (0) 2234 6039 102

Fax. +49 (0) 2234 6039 101

[email protected]

Össur Head Office
Grjótháls 5
110 Reykjavík, Iceland
Tel: +354 515 1300
Fax: +354 515 1366
[email protected]

WWW.OSSUR.COM

©Copyright Össur 2016

Rev. 6

TM 0056   EN   /   1020_002

Содержание PROPRIO FOOT

Страница 1: ...PROPRIO FOOT Technical Manual...

Страница 2: ...uction 7 Technical specifications 7 Setup 8 Basic operation 11 Calibration 13 Functions 14 Advanced operation 15 Maintenance 16 Training tips 17 Warranty 17 Electromagnetic compatibility precautions 1...

Страница 3: ...3 1 3 1 3 1 3 1 2 1 2 1 2 1 2 1 2 1 2 a b c d e f...

Страница 4: ...2 1 start 1 move 1 complete Move to neutral relax 4 1 relax Manual motor movement 6 n a Sound on off 7 1 on calibration on off 9 1 on off Default manufacturer setting Stair Mode 4 Stair mode Sequence...

Страница 5: ...and should never be disposed of in residential or commercial garbage They should never be incinerated because they may explode Perform field servicing at the recommended intervals according to the in...

Страница 6: ...mpanying documents Consult Instructions for use Meets IEC type B leakage current requirements CE label with Notified Body indentification number Must be disposed of or recycled properly Connection for...

Страница 7: ...le environmental conditions are described in the technical specifications see Technical specifications proprio foot is suitable for continuous use The proprio foot may only be fitted by a qualified an...

Страница 8: ...attery in the most proximal position possible Avoid flexion limitations to the knee Check the position using the dummy The position of the battery assembly may vary on individual sockets Care must be...

Страница 9: ...ion during walking and make changes if necessary to the assembly BENCH ALIGNMENT Figure F Overview Fit the foot with the selected cover and shoe Power ON see chapter Power ON Adjust the Heel Height to...

Страница 10: ...ely note do not use a Flex Foot shoe horn or any other lever to remove the foot cover as this may cause damage to the ankle unit CHARGING AND POWER Figure K Only use the power supply supplied for prop...

Страница 11: ...d will be disabled after 60 seconds from use To enable the keypad hold both buttons at least for one second When proprio foot is activated for the first time the default manufacturer settings will be...

Страница 12: ...te If the heel height exceeds 50mm 2 a signal will be heard and the unit will not adjust to the heel height Change shoes for lower heel height and repeat the adjustment Ensure free ankle motion Heel h...

Страница 13: ...d until completion of calibration is confirmed by a beep and vibration The LED blinks green The system is now properly calibrated to the user and enabled for normal adaptive functions note Make sure t...

Страница 14: ...lting in unexpected ankle adaptation STAIRS During stair ascent proprio foot will raise the toe This will facilitate stair ambulation and improve gait symmetry When leading with the prosthetic side pr...

Страница 15: ...Mode the proprio foot will move into CHAIR EXIT MODE To initiate this use one of the following methods 1 Tap the heel of the foot 2 Flex the knee and place the foot beneath the chair Lift the foot to...

Страница 16: ...m confirms with a beep and vibration when enabled There is no confirmation when sound is disabled MAINTENANCE SERVICE proprio foot is designed and manufactured to provide long and trouble free service...

Страница 17: ...rosthetic side upstairs and to lead with the prosthetic side when going down This will provide stair adaptation after the first step on stairs Note Instruct the user to be careful walking downstairs f...

Страница 18: ...air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2kV for powe...

Страница 19: ...RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the fol...

Страница 20: ...distance between portable and mobile RF communications equipment transmitters and the device as recommended below according to the maximum output power of the communications equipment Rated maximum ou...

Страница 21: ...evel Category ssur high activity Category Weight Kg Lable text 1 52 P3 ISO 10328 P3 52 kg 2 59 P3 ISO 10328 P3 59 kg 3 68 P4 ISO 10328 P4 68 kg 4 77 P4 ISO 10328 P4 77 kg 5 88 P4 ISO 10328 P5 88 kg 6...

Страница 22: ......

Страница 23: ...with other recommended ssur components If un usual movement or product wear is detected in a structural part of a device at any time the patient should be instructed to immediately discontinue use of...

Страница 24: ...6127 1799 Fax 1 866 441 3880 Madrid Espa a asia ossur com Tel 00 800 3539 3668 ssur Europe BV Fax 00 800 3539 3299 ssur Australia De Schakel 70 orders spain ossur com 26 Ross Street 5651 GH Eindhoven...

Отзывы: