23
Test mode
At Startup Setting and Offline Setting, the setting “send MARK” sends a
MARK (a logical one) on the bus: no data are sent to the fixtures and the
DMX port awaits further commands.
You can also capture content (snapshots) and use it for Startup and Offline
Settings:
By assigning a Group ID to multiple SYMPL pro Nodes (e:pix) /
SYMPL essential Nodes, the content of all identically assigned
SYMPL pro Nodes (e:pix) / SYMPL essential Node is captured and likewise
displayed on these devices.
Running Startup Setting is indicated by flashing DMX/RDM status LEDs.
Please note that when you select an content image (snapshot) at these
settings, the framerate of the displayed image is reduced to 20 FPS.
6 Test mode
- SYMPHOLIGHT v5.0 or higher needed-
The SYMPL pro Node (e:pix) / SYMPL essential Node provides a Test mode
for the connected DMX devices. The Test mode is designed for DMX
luminaires. There are two kinds: using the Test button and using the web
interface of the SYMPL pro Node (e:pix) / SYMPL essential Node.
Please note that the Test mode overwrites all other DMX output like running
shows, Startup Setting’s or Offline Setting’s output for the time of testing. A
running show, the Startup and the Offline output respectively are reverted to
2. Employ