- 3 -

1.   To obtain the best performance from your OSO unvented system it is advisable to feed the unit 

 

with an uninterrupted supply.

2.   Before connecting to the multibloc, flush the cold supply pipework of all flux and debris.

3.   Locate the water heater in a suitable position to facilitate the installation of the cold water supply, 

 

discharge fittings and pipework. Also take into account access to the immersion heaters and the 

 

commissioning valve.

4.   Fit both 1/2’’ male heat pump sensor pockets to the Sensor Pocket bosses (12&21).

10. Remove the appropriate nuts and rings and connect the flexible hose to the expansion relief valve 

 

and the right pointing T-piece connection.

11. If a balanced mains pressure cold water supply is required to a shower or bidet (over rim type 

 

only), remove the blanking cap from the pressure reducing valve (3) and connect to the shower 

 

or bidet cold supply. 

Do not use the balanced cold connection to feed bath taps as this can reduce 

 

the flow available to the unvented cylinder. 

12. Connect the cold supply to the Multibloc (3).

13. Fit the expansion vessel to the wall close to the water heater using the enclosed mounting bracket. 

 

Connect the expansion vessel hose to the T piece in the cold feed pipe to the cylinder. 

 

The expansion vessel is supplied with the OSO unit, fit as shown on page 2.

Hot water supply

14. Connect the hot water supply pipe to the outlet (9). Ensure connection is water tight.

 

Secondary return (optional)

15. Connect secondary return (if required) by fitting a T-piece (not supplied) into the cold feed tube (8) 

 

according to diagram on page 16. 

Discharge pipe

16. Connect the discharge pipe from the tundish (6). This must have a continuous fall and be fitted 

 

in accordance with The Building Regulations (see page 16). The tundish should be installed away 

 

from electrical devices.

Primary flow & return & motorised valve - heat pump

17. The heat pump primary flow and return connections should be made to the unit. The motorised valve 

 

must be fitted either on the flow or return of the primary water heating circuit. The primary flow and 

 

return connections are ¾” female. The valve has 22mm copper connections. The direction of the 

 

primary flow in the coil is top to bottom.

200 litre cylinder:

5.   Fit the combined male elbow drain cock to 

 

cold supply point (13), so that the compress-

 

ion fitting is horizontal point to the right.

6.   Fit the length of copper tube 22mm specified 

 

in table 2 to the cold feed elbow with a right 

 

angle bend as shown to include a T piece for 

 

the expansion vessel. 

7.   Fit the pressure reducing valve to the top of 

 

the copper tube so that the black knob is 

 

facing right.

8.   Fit a 15mm copper tube to the T & P valve 

 

and bend around the top of the cylinder to 

 

pass close and 50 mm to the left of the cold 

 

feed pipe. Cut the pipe off 700 mm from the 

 

floor. Fit the compression end of the T piece 

 

to the bottom of the 15mm copper pipe with 

 

the female end pointing down and the right 

 

angle connection pointing 45° to the right.

9.   Remove the nut and ring from the top 

 

connection of the tundish and screw the male 

 

thread into the female thread of the T piece.

250 & 300 litre cylinder:

5.   Fit the combined male elbow drain cock to 

 

cold supply point (13), so that the compress-

 

ion fitting is vertical.

6.   Fit the length of copper tube 22mm specified 

 

in Table 2 to the cold feed elbow (see 5 

 

above) to include a T piece for the expansion 

 vessel. 

7.   Fit the pressure reducing valve to the top of 

 

the copper tube so that the black knob is 

 

facing right.

8.   Fit the female outlet of the tee piece to the 

 

temperature and pressure relief valve (5) with 

 

the horizontal connection facing right at 

 

approx. 45°.

9.   Fit the tundish to the T piece using a short 

 

length of copper tube.

COLD WATER SUPPLY

Содержание Ecoline Geo RI HP

Страница 1: ...ource information is included in this manual to link the cylinder with the heat pump This cylinder is manufactured and approved in accordance with EN 12897 2006 This manual gives detailed advice for i...

Страница 2: ...2 9 Hot Water Outlet 3 4 BSPF 10 Flexible Hose 202108 11 Flexible Hose for Expansion Vessel Not supplied 12 Sensor Pocket 1 2 13 Elbow Drain Cock 250445 14 Cable Entry 15 Electrical Box 16 Tee Piece 2...

Страница 3: ...tundish should be installed away from electrical devices Primary flow return motorised valve heat pump 17 The heat pump primary flow and return connections should be made to the unit The motorised val...

Страница 4: ...pleted ensure the lid to the electrical box is replaced correctly and the retaining screw is fitted 4 If still out of operation contact installer Cold or tepid water discharge from tundish The tundish...

Страница 5: ...o suit the installation as long as it is fitted in the correct flow direction Check the flow arrows on the side of the body 4 The expansion valve should be either horizontal or pointing downwards If f...

Страница 6: ...tted length of 22mm pipework is 9m Each bend or elbow is equivalent to 0 8m of pipework All pipework must have continuous fall and discharge in a safe visible position If any doubt refer to Building R...

Страница 7: ...ch immersion heater has a working thermostat adjustable between 40 C 70 C A safety cut out is also incorporated within the thermostat and will operate at 85 C 3 C Should this happen press the reset bu...

Страница 8: ...8 Heat pump...

Страница 9: ...9 00071259 00071259 Direct units Indirect units Thermostat 80020 Right thermostat 80030 Left thermostat 80020 Immersion heater 71259 Immersion heater 71259 Electrical spare parts...

Страница 10: ...as operated 4 Programmer set to central heating or not switched on 5 Cylinder thermal cut out has operated 6 Motorised valve not operating correctly 1 Check Heat Pump operation If fault suspected cons...

Страница 11: ...11 Is the heat pump working Is Thermostat wired as per layout for S plan installation...

Страница 12: ...blocks of flats the number served should be limited to not more than 6 systems so that any installation discharging can be traced reasonably easily The single common discharge pipe should be at least...

Страница 13: ...13 C O L L E C T I V E M A R K TM...

Страница 14: ...3 The benchmark certificate is completed at the time of installation 4 The OSO cylinder is serviced and maintained every 12 months and is marked as such in the benchmark logbook provided with the cyl...

Страница 15: ...15 C C...

Страница 16: ...COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME TEL No TEL No TEL No TEL No TEL No TEL No TEL No TEL No TEL No TEL No COMMENTS COM...

Отзывы: