background image

- 14 -

The OSO stainless steel inner vessel is guaranteed against material defect or manufacturing faults for a period of 25 years from 

the date of purchase. All other parts including, but not limited to factory fitted electrical elements (damage caused by lime scale 

excluded), expansion vessel, thermostats and valves are guaranteed against material defects or manufacturing faults for 2 years 

from the date of purchase. In the event of a replacement component being required OSO Hotwater will supply such part(s) free 

of charge and freight paid, on condition that the defective component is delivered, freight paid to OSO Hotwater within 2 weeks 

of written notice being given to OSO Hotwater of the defect. Such replacement parts shall be guaranteed under the terms of this 

guarantee to the unexpired period of the aforementioned 2 year period.

This warranty is conditional upon the OSO cylinder being installed in compliance with the OSO Installation & Maintenace Instructions, 

all current legislation, codes of practice and regulations governing the installation of unvented hot water cylinders in force at the date of 

installation and provided that: 

1.  The water quality shall be in accordance with European Council Directive 98/83 EC, or revised version at the date of installation,

   and is not fed with water from a private supply. 

  Particular: Chloride content: 

 

 

Max. 250 mg/l

   

 

Sulphate content: 

 

 

Max. 250 mg/l

   

 

Combination Chloride/sulphate: 

Max. 300 mg/l (in total)

2.  The OSO cylinder is filled with water before turning the electricity supply on to the heater elements.

3.  The benchmark certificate is completed at the time of installation.

4.  The OSO cylinder is serviced and maintained every 12 months and is marked as such in the benchmark logbook provided

  with the cylinder. Invoices for the maintenance work should be kept as proof of regular maintenance. Care should be taken

  of the logbook and invoices as they serve as the guarantee certificate for the cylinder. 

5.  If the newly fitted water heater is not in regular use then it must be flushed through with fresh water for at least 15 minutes. 

  Open at least one hot water tap once per week, during a period of at least 4 weeks. 

6.  The OSO unvented cylinder has not been modified in any way other than by OSO Hotwater and is only used for the storage 

  of potable water.

7.  No factory fitted parts have been removed for unauthorised repair or replacement.

8.  Defects caused by frost, excess pressure, salt dehardner process, transient voltage, lightning strikes or incorrect installation, 

  repair or use, are not covered by this warranty. A laboratory evaluation of possible defects can be ordered by the user, 

  however the user must pay for this where the above mentioned conditions have not been fulfilled. Evidence of the purchase 

  date and the date of supply must also be submitted with your claim.

9.  To validate the warranty the user must complete and return the warranty card supplied accompanied by proof of purchase 

  within 60 days of purchase. Evidence of the purchase date and the date of supply / installation must be submitted.

This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential 

loss or damage. This guarantee is offered as an extra benefit and does not affect your statutory rights as a consumer.

Содержание Ecoline Geo RI HP

Страница 1: ...ource information is included in this manual to link the cylinder with the heat pump This cylinder is manufactured and approved in accordance with EN 12897 2006 This manual gives detailed advice for i...

Страница 2: ...2 9 Hot Water Outlet 3 4 BSPF 10 Flexible Hose 202108 11 Flexible Hose for Expansion Vessel Not supplied 12 Sensor Pocket 1 2 13 Elbow Drain Cock 250445 14 Cable Entry 15 Electrical Box 16 Tee Piece 2...

Страница 3: ...tundish should be installed away from electrical devices Primary flow return motorised valve heat pump 17 The heat pump primary flow and return connections should be made to the unit The motorised val...

Страница 4: ...pleted ensure the lid to the electrical box is replaced correctly and the retaining screw is fitted 4 If still out of operation contact installer Cold or tepid water discharge from tundish The tundish...

Страница 5: ...o suit the installation as long as it is fitted in the correct flow direction Check the flow arrows on the side of the body 4 The expansion valve should be either horizontal or pointing downwards If f...

Страница 6: ...tted length of 22mm pipework is 9m Each bend or elbow is equivalent to 0 8m of pipework All pipework must have continuous fall and discharge in a safe visible position If any doubt refer to Building R...

Страница 7: ...ch immersion heater has a working thermostat adjustable between 40 C 70 C A safety cut out is also incorporated within the thermostat and will operate at 85 C 3 C Should this happen press the reset bu...

Страница 8: ...8 Heat pump...

Страница 9: ...9 00071259 00071259 Direct units Indirect units Thermostat 80020 Right thermostat 80030 Left thermostat 80020 Immersion heater 71259 Immersion heater 71259 Electrical spare parts...

Страница 10: ...as operated 4 Programmer set to central heating or not switched on 5 Cylinder thermal cut out has operated 6 Motorised valve not operating correctly 1 Check Heat Pump operation If fault suspected cons...

Страница 11: ...11 Is the heat pump working Is Thermostat wired as per layout for S plan installation...

Страница 12: ...blocks of flats the number served should be limited to not more than 6 systems so that any installation discharging can be traced reasonably easily The single common discharge pipe should be at least...

Страница 13: ...13 C O L L E C T I V E M A R K TM...

Страница 14: ...3 The benchmark certificate is completed at the time of installation 4 The OSO cylinder is serviced and maintained every 12 months and is marked as such in the benchmark logbook provided with the cyl...

Страница 15: ...15 C C...

Страница 16: ...COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME COMPANY NAME TEL No TEL No TEL No TEL No TEL No TEL No TEL No TEL No TEL No TEL No COMMENTS COM...

Отзывы: