11
RECOMMENDATION
- The mains cable supplied should be used with fixed electric fittings by removing the plug for the
wall socket. (Heat-resistant)
- Mains cable for wall socket/wall box should be hidden under one of the channels in the bottom of
the product.
-
For products with ≤ 2kW capacity, a
> 10A fuse / > 1.5# wire should be used*.
For products with ≤ 3kW capacity, a
> 15A fuse / > 2.5# wire should be used (230V).
3.6.4 Fitting instructions
3.6.5 Fitting recommendation
!
WARNING
!
The product should be filled with water before the power is switched on.
!
Fixed electric fittings should be used for installation in new homes or when changing an existing
electrical setup in accordance with regulations. A mains cable with plug for wall socket can be
used when replacing the product without changing the electrical setup.
!
The mains cable should withstand 90°C. A strain reliever must be fitted.
!
CAUTION
!
The product must have a clearance for servicing of 40 cm in front of the cover / 10 cm
over the mixer valve.
!
In case of damage to the mains cable and plug, it should be replaced with a specially adapted
mains cable from the manufacturer.