4
1.3 Safety instructions for installers
1.2 Safety instructions for users
!
WARNING
The overflow from the safety valve must NOT be sealed or plugged.
The product must NOT be covered over the electric junction box covers on the front.
The product must NOT be modified or changed from its original state.
Children must NOT play with the product or go near it without supervision.
!
The product shall be filled with water before the power is switched on.
!
Maintenance/settings should only be carried out by persons over 18 years of age, with sufficient
understanding
!
CAUTION
The product must not be exposed to frost, over-pressure, over-voltage or chlorine treatment.
See warranty provisions.
Maintenance/settings shall not be carried out by persons of diminished physical or mental capac-
ity, unless they have been instructed in the correct use by someone responsible for their safety.
!
WARNING
The overflow from the safety valve shall NOT be sealed or plugged.
!
The discharge pipe from any safety device shall be at least one pipe size larger than the
nominal outlet size of the safety device (< 9m length). The discharge pipe shall have
continuous fall to drain, be uninterruptable and frost-free at all times.
!
The electrical supply to the heater shall be done in accordance with current local regula-
tions and best practice by a qualified electrician. The product is intended for permanent
supply.
!
The mains power supply cable shall withstand 90°C. A strain reliever shall be fitted.
!
The product shall be filled with water before the power is switched on.
!
The relevant regulations and standards, and this installation manual, shall be followed.
!
CAUTION
!
The product shall be placed in a room with a floor drain.
The manufacturer assumes no responsibility whatsoever if this provision is not followed.
!
The product shall be properly aligned vertically and horizontally, on a floor or suitable for the
total weight of the product when in operation. See type plate.
!
The product shall have a clearance for servicing of 40 cm in front of the electric cover / 10 cm
over the highest point.