CAS80R
SECTION 6: TROUBLESHOOTING
Manual # 99905932 (February 2016)
PAGE - 31
®
IOWA MOLD TOOLING CO., INC.
(641) 923-3711 • www.imt.com
Insufficient air delivery
Plugged air filter
Replace air filter.
Plugged coalescer (air/oil
separator)
Replace coalescer element.
Motor speed to low
Check hydraulic flow and pressure and
adjust if necessary.
Inlet valve stuck closed.
Free or replace inlet valve. Order
rebuild kit if necessary.
Defective regulator
Replace regulator.
Stuck minimum pressure valve
Free or replace valve.
Oil carryover
Oil level overfull
Drain to proper level.
Plugged oil scavenge line
Remove and clean strainer thoroughly.
See Section 7.2A, P/N 271054.
Discharge pressure too low
Check minimum pressure valve and
adjust. Replace if necessary.
Defective coalescer
Replace coalescer element.
Overspeeding
Readjust speed.
Incorrect oil used
Drain and replace with proper oil.
Compressor overheating
Check oil level and fill to proper level.
Reposition machine to assure proper
air flow.
Check ground connection and ensure
proper connection.
Check fan switch.
Check circuit breaker.
Check for short in wires.
Check fan motor.
Plugged oil filter
Replace oil filter.
Cooler core plugged
Clean cooler core.
Pressure set too high
Contact factory service department.
Contaminated cooler core
Remove and clean cooler core.
Unit running too fast
Check hydraulic flow and pressure and
adjust if necessary.
Thermal valve
Faulty valve; replace thermal valve.
Incorrect oil used
Drain and replace with proper oil.
Continued on next page
6.2 TROUBLESHOOTING GUIDE
MALFUNCTION/FAULT
POSSIBLE CAUSE
CORRECTIVE ACTION
Содержание IMT CAS80R
Страница 66: ...BLANK PAGE...
Страница 67: ...BLANK PAGE...