SECTION 3: INSTALLATION
Manual # 99905932 (February 2016)
PAGE - 9
IOWA MOLD TOOLING CO., INC.
(641) 923-3711 • www.imt.com
®
Figure 3-1: Unit Mounting Types
A
B
KEY
DESCRIPTION
A
OPEN-MOUNTING TYPE LOCATION
B
ENCLOSED-MOUNTING TYPE LOCATION
platform; removable enclosure walls, etc.).
For
enclosed-mountings,
it
is
also
recommended to install a safety switch on
the access door that allows for compressor
operation only when the door is open.
The unit must have a minimum additional six
inch (6”) unobstructed clearance on all sides
of the machine for operation.
Ideal ventilation regardless of the type of
mounting installation of the unit, needs to
provide adequate, unrestricted air flow
through the unit. Additionally, the cooler must
be exposed to, or provided with (ducted),
cool ambient air, and an exhaust fan within
the enclosed space to displace the heated
air.
3.6 HYDRAULIC
REQUIREMENTS
The hydraulic pump must be rated for 2,900
psi consistent operation, and 3,300 psi for
pressure spikes.
The compressor capacity will depend on
hydraulic oil flow.
If the compressor is being installed on a truck
that already has a functioning hydraulic
system, check the specifications for that
system to ensure that it meets minimum
requirements.
IMPORTANT
DO NOT mount Hydraulic Reservoir in same
enclosed space as the machine.
Installing enclosed-mounting type without
proper cooling air ducted to coolers is NOT
RECOMMENDED.
IMPORTANT
The relief valve is set to 3,300 psi. The pump
must be rated for this relief valve setting.
NOTE
The values depicted in TABLE 2A are
referential only: Due to the variable
relationship between CFM output and
hydraulic flow, adjustments should be
tested to achieve the desired CFM output in
regard to flow, load and system efficiency.
NOTE
The information in this manual is in regard
to a fixed displacement pump. For systems
utilizing a variable displacement pump,
consult a qualified hydraulic system
specialist.